Specializing in the production of insulation products

LZJ8-10 Current Transformer 10kV Indoor HV CT – 5-1000A 0.2S/0.5S/10P Class 100×In Thermal 250×In Dynamic 12/42/75kV Epoxy Resin GB1208 IEC60044-1

Description:

LZJ8-10 Current Transformer 10kV Indoor HV CT: 5-1000A primary current, 0.2S/0.5S/10P10/10P15 accuracy class, 100×In thermal capacity for 50-400A, 250×In dynamic current, 12/42/75kV insulation level, 10-15VA burden, 5A/1A secondary, 50/60Hz, GB1208 IEC60044-1 compliant, metering & protection.

Applications:

Advanced LZJ8-10 Current Transformer: Indoor single-phase epoxy resin casting type CT conforming to GB1208 and IEC60044-1 standards, rated insulation level 12/42/75kV, rated frequency 50Hz or 60Hz, rated secondary current 5A or 1A, ambient temperature -5°C to +40°C, rated primary current range 5-1000A providing comprehensive current coverage, flexible accuracy class combinations including 0.2(S)/10P and 0.5(S)/10P with burden capacity 10-15VA, exceptional thermal performance with 90-100×In (1s thermal current) for 5-400A range ensuring superior short-circuit withstand capability, 220-250×In rated dynamic current for 5-400A providing maximum safety margin, flexible protection classes including 10P10 and 10P15 supporting diverse relay protection requirements.

Superior Thermal Capacity and Wide Current Range: LZJ8-10 features exceptional 90-100 times rated current thermal capacity for low-medium current range (5-400A) ensuring outstanding short-circuit protection, rated dynamic current up to 220-250×In for 5-400A range providing maximum safety margin, 1s thermal current 50-80kA for higher ranges (500-1000A) with rated dynamic current 100-130kA, flexible protection classes (10P10/10P15) enabling diverse relay protection applications, suitable for 10kV switchgear, MV power distribution systems, substation metering, relay protection, energy management systems, industrial power monitoring, and applications requiring precise current measurement from 5A to 1000A with exceptional thermal withstand capability and flexible protection configurations.

Specifications

LZJ8-10 Current Transformer 10kV Indoor HV CT - 5-1000A 0.2S 0.5S 10P Class 100×In Thermal 250×In Dynamic 12 42 75kV Epoxy Resin GB1208 IEC60044-1

Features

LZJ8-10 Current Transformer Specifications Parameter Unit
Brand Bepto Insulation Systems
Model Number LZJ8-10
Category Switchgear & HV CT (High Voltage Current Transformer)
Product Type 10kV Indoor Single-Phase Epoxy Resin Casting Type Current Transformer with 5-1000A Range, 100×In Thermal Capacity, 250×In Dynamic Current, 0.2S/0.5S/10P Accuracy Class, 10P10/10P15 Protection Classes, 12/42/75kV Insulation for Metering & Relay Protection
Core Technology Indoor Single-Phase Epoxy Resin Casting Type + 10kV High Voltage Design + Exceptional 90-100×In Thermal Capacity for 5-400A Range + Superior 220-250×In Dynamic Current for 5-400A Range + GB1208 and IEC60044-1 Standards Compliant + Rated Insulation Level 12/42/75kV + Rated Frequency 50Hz or 60Hz + Rated Secondary Current 5A or 1A + Ambient Temperature -5°C to +40°C + Rated Primary Current Range 5-1000A + Comprehensive Current Coverage + Flexible Accuracy Classes (0.2(S)/10P, 0.5(S)/10P) + Flexible Protection Classes (10P10, 10P15) + Burden Capacity 10-15VA + 1s Thermal Current 50-80kA for Higher Ranges + Rated Dynamic Current 100-130kA + Simultaneous High-Precision Metering and Protection Functions + Superior Short-Circuit Withstand Capability + Maximum Safety Margin + Diverse Relay Protection Requirements
Power (Voltage) 10kV
Rated Voltage 10kV
Rated Insulation Level 12/42/75 kV
Rated Frequency 50Hz or 60Hz Hz
Rated Secondary Current 5A or 1A A
Rated Primary Current Range 5-1000 A
Ambient Temperature -5°C to +40°C °C
Structure Type Indoor Single-Phase Epoxy Resin Casting Type
Installation Type Indoor
Phase Single Phase
Standards Compliance GB1208 and IEC60044-1
FOB Port Ningbo/Shanghai
Terms of Payment Western Union, T/T, Paypal
Epoxy Resin Casting Yes (Indoor Single-Phase Epoxy Resin Casting Type)
10kV High Voltage Yes (10kV Rated Voltage)
HV CT Yes (High Voltage Current Transformer)
100×In Thermal Capacity Yes (100×In Thermal Current for 50-400A Range)
250×In Dynamic Current Yes (250×In Dynamic Current for 50-400A Range)
Exceptional Thermal Performance Yes (Superior Short-Circuit Withstand Capability)
Flexible Protection Classes Yes (10P10 and 10P15 Protection Classes Available)
Maximum Safety Margin Yes (220-250×In Dynamic Current for Maximum Safety)
50Hz or 60Hz Yes (Rated Frequency 50Hz or 60Hz)
10kV Rated Voltage Yes (Rated Voltage 10kV)
GB1208 Compliant Yes (In Accordance with GB1208 Standard)
IEC60044-1 Compliant Yes (In Accordance with IEC60044-1 Standard)
12/42/75kV Insulation Yes (Rated Insulation Level 12/42/75kV)
5A or 1A Secondary Yes (Rated Secondary Current 5A or 1A)
-5°C to +40°C Ambient Yes (Ambient Temperature -5°C to +40°C)
5-1000A Primary Range Yes (Rated Primary Current Range 5-1000A)
Comprehensive Current Coverage Yes (From 5A to 1000A Primary Current)
0.2S Accuracy Class Yes (0.2S Metering Accuracy Class Available)
0.5S Accuracy Class Yes (0.5S Metering Accuracy Class Available)
10P10 Protection Class Yes (10P10 Protection Accuracy Class Available)
10P15 Protection Class Yes (10P15 Protection Accuracy Class Available)
10-15VA Burden Capacity Yes (Burden Capacity 10-15VA)
Rated primary current (A) Accuracy classes combination 0.2S / 0.5S (VA) 0.2 (VA) 0.5 (VA) 10P10 (VA) 10P15 (VA) 1s thermal current (kA) Rated dynamic current (kA)
5–40 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 15 90 × In 220 × In
50–400 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 15 100 × In 250 × In
500 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 15 50 100
600 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 15 56 110
800 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 15 75 110
1000 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 15 80 130
Rated Primary Current (A) 90×In Thermal Current (kA) 220×In Dynamic Current (kA)
5 0.45 1.1
10 0.9 2.2
15 1.35 3.3
20 1.8 4.4
25 2.25 5.5
30 2.7 6.6
40 3.6 8.8
Rated Primary Current (A) 100×In Thermal Current (kA) 250×In Dynamic Current (kA)
50 5 12.5
60 6 15
75 7.5 18.75
80 8 20
100 10 25
150 15 37.5
200 20 50
250 25 62.5
300 30 75
400 40 100
Primary Current Range Thermal/Dynamic Capacity Protection Classes Application
5-40A 90×In / 220×In 10P10, 10P15 Low current with exceptional thermal protection and flexible protection classes
50-400A 100×In / 250×In 10P10, 10P15 Medium current with maximum thermal capacity and flexible protection classes
500A 50kA / 100kA 10P10, 10P15 High current with stable performance and flexible protection classes
600A 56kA / 110kA 10P10, 10P15 High current with enhanced thermal capacity and flexible protection classes
800A 75kA / 110kA 10P10, 10P15 Very high current with maximum protection and flexible protection classes
1000A 80kA / 130kA 10P10, 10P15 Ultra-high current with comprehensive protection and flexible protection classes
Protection Class Accuracy Limit Factor (ALF) Application Scenario Typical Current Range
10P10 10 Standard relay protection with 10× rated current accuracy 5-1000A
10P15 15 Enhanced relay protection with 15× rated current accuracy 5-1000A
Accuracy Classes Combination Application Scenario Typical Current Range
0.2(S)/10P High-precision metering + flexible protection (10P10/10P15) 5-1000A
0.5(S)/10P Standard metering + flexible protection (10P10/10P15) 5-1000A

Let The World Know About Bepto

Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.

Application

ANYTHING YOU COULDN’T FIND?
Talk With Our Sales

Bepto focuses on the global market and provides our clients with products suitable for the local market:

SEND US AN EMAIL
Contact Us

Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.

Form Contact 2
Bepto Logo red
Get More Benefits Since Submit The Info Form
Form Contact