Specializing in the production of insulation products

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – Anti-Magnet Ferroresonance Suppression 100V/√3+100V/√3 Triple Secondary 0.2/0.5/1/3/6P Class 3×400VA GB1207

Description:

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, anti-magnet ferroresonance suppression, 3kV-10kV/√3/100V/√3+100V/√3 ratio, triple secondary winding, 0.2/0.5/1/3/6P accuracy class, 3.6-12/25-42/40-75kV insulation, 3×400VA thermal limit output, 310mm creepage, 50-60Hz, GB1207 IEC60044-2.

Applications:

Advanced JSZJK indoor three-phase anti-magnet anti-resonance voltage transformer featuring epoxy resin casting, conforming to GB1207 and IEC60044-2 standards, three voltage levels (3kV, 6kV, 10kV), rated insulation levels 3.6/25/40kV, 7.2/32/60kV, and 12/42/75kV, rated frequency 50Hz or 60Hz, designed for indoor ungrounded or resonant grounded systems with ferroresonance suppression capability, 100V/√3 dual secondary measuring windings plus 100V/√3 residual voltage winding for comprehensive voltage measurement and grounding protection.
Superior anti-magnet design eliminates ferroresonance overvoltage risks in indoor ungrounded systems, exceptional 3×400VA thermal limit output capacity supports extensive indoor multiple load connections, triple secondary winding configurations (JDZJK series) available for dual metering plus grounding protection, 310mm creepage distance ensures reliable insulation performance, compact three-phase integrated design reduces indoor installation space and costs, suitable for indoor substations, indoor switchgear, and metal-clad equipment requiring reliable ferroresonance suppression and grounding protection.

Specifications

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT - Anti-Magnet Ferroresonance Suppression 100V/√3+100V/√3 Triple Secondary 0.2/0.5/1/3/6P Class 3×400VA GB1207

Features

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer Specifications Parameter Unit
Brand Bepto Insulation Systems
Model Number JSZJK-3/6/10 Series (JSZJK-3, JSZJK-6, JSZJK-10, JDZJK-3, JDZJK-6, JDZJK-10)
Category Switchgear & HV PT (High Voltage Potential Transformer)
Product Type 3kV/6kV/10kV Indoor Three-Phase Anti-Magnet Anti-Resonance Epoxy Resin Casting Voltage Transformer with Ferroresonance Suppression, Triple Secondary Winding, 0.2/0.5/1/3/6P Accuracy Class, 3.6-12/25-42/40-75kV Insulation, 3×400VA Thermal Limit Output for Indoor Ungrounded Systems Voltage & Energy Measurement and Grounding Protection
Core Technology Indoor Three-Phase Anti-Magnet Anti-Resonance Epoxy Resin Casting Design + Ferroresonance Suppression Technology + Multi-Voltage Flexibility (3kV/6kV/10kV) + Integrated Three-Phase Configuration + GB1207 and IEC60044-2 Standards Compliant + Rated Insulation Levels (3.6/25/40kV, 7.2/32/60kV, 12/42/75kV) + Rated Frequency 50Hz or 60Hz + Phase-to-Ground Voltage Ratio (3kV-10kV/√3/100V/√3+100V/√3) + Triple Secondary Winding Configuration + Accuracy Classes (0.2, 0.5, 1, 3, 6P/3P) + Rated Secondary Load 3×10-3×150VA + Thermal Limit Output 3×200-3×400VA + 310mm Creepage Distance + Compact Three-Phase Integrated Design + Proven Anti-Magnet Anti-Resonance Technology
Power (Voltage) 3kV / 6kV / 10kV
Installation Type Indoor
Phase Three Phase (Integrated)
Structure Type Single-Phase Units (Three Required for Three-Phase System)
Rated Voltage (JSZJK-3) 3kV/√3 (1.73kV) per phase
Rated Voltage (JSZJK-6) 6kV/√3 (3.46kV) per phase
Rated Voltage (JSZJK-10) 10kV/√3 (5.77kV) per phase
Voltage Ratio (JSZJK Dual) 3kV-10kV/√3/0.1/√3/0.1 kV
Voltage Ratio (JDZJK Triple) 3kV-10kV/√3/0.1/√3/0.1/√3/0.1 kV
Secondary Measuring Winding 1 100V/√3 (57.7V) V
Secondary Measuring Winding 2 100V/√3 (57.7V) V
Residual Voltage Winding 100V/√3 (57.7V) V
Rated Frequency 50Hz or 60Hz Hz
Accuracy Classes 0.2, 0.5, 1, 3, 6P (3P)
Insulation Level (JSZJK-3) 3.6/25/40 kV
Insulation Level (JSZJK-6) 7.2/32/60 kV
Insulation Level (JSZJK-10) 12/42/75 kV
Thermal Limit Output (JSZJK Dual) 3×400 VA
Thermal Limit Output (JDZJK Triple) 3×200 VA
Rated Secondary Load (0.2 Class) 3×20 VA
Rated Secondary Load (0.5 Class) 3×50 VA
Rated Secondary Load (1 Class) 3×80 VA
Rated Secondary Load (3 Class) 3×150 VA
Rated Secondary Load (6P/3P Class) 100 VA
Rated Secondary Load (0.2/0.2 Triple) 3×10/3×10 VA
Rated Secondary Load (0.2/0.5 Triple) 3×10/3×15 VA
Rated Secondary Load (0.5/0.5 Triple) 3×20/3×20 VA
Creepage Distance 310 mm
Weight 82 kg
Insulation Type Indoor Epoxy Resin Casting
Anti-Resonance Technology Anti-Magnet Ferroresonance Suppression Design
Voltage Level Low-Medium Voltage (3kV/6kV/10kV)
Standards Compliance GB1207 and IEC60044-2
FOB Port Ningbo/Shanghai
Terms of Payment Western Union, T/T, Paypal
Multi-Voltage 3kV/6kV/10kV Yes (Three Voltage Levels Available)
Indoor Three-Phase Yes (Indoor Three-Phase Application)
Anti-Resonance Yes (Ferroresonance Suppression Technology)
Anti-Magnet Yes (Anti-Magnet Design)
Indoor Epoxy Resin Casting Yes (Indoor Epoxy Resin Casting Insulation)
3×400VA Thermal Output Yes (3×400VA Thermal Limit Output for Dual Secondary)
100V/√3+100V/√3 Ratio Yes (Dual Measuring Windings + Residual Voltage Winding)
Triple Secondary Winding Yes (Triple Secondary Available in JDZJK Series)
Ferroresonance Suppression Yes (Anti-Magnet Anti-Resonance Design)
Grounding Protection Yes (100V/√3 Residual Voltage Winding)
310mm Creepage Distance Yes (310mm Surface Creepage Distance)
50Hz or 60Hz Yes (Rated Frequency 50Hz or 60Hz)
GB1207 Compliant Yes (In Accordance with GB1207 Standard)
IEC60044-2 Compliant Yes (In Accordance with IEC60044-2 Standard)
3.6-12/25-42/40-75kV Insulation Yes (Rated Insulation Levels)
0.2 Accuracy Class Yes (0.2 Metering Accuracy Class Available)
0.5 Accuracy Class Yes (0.5 Metering Accuracy Class Available)
1 Accuracy Class Yes (1 Monitoring Accuracy Class Available)
3 Accuracy Class Yes (3 Monitoring Accuracy Class Available)
6P/3P Protection Class Yes (6P/3P Protection Accuracy Class Available)
Compact Design Yes (Three Single-Phase Units for Three-Phase System)
JSZJK Series (Indoor three-phase anti-ferromagnetic, anti-resonance with dual secondary windings)
Model Type Rated Voltage Voltage Ratio Insulation Level Thermal Limit Output Application
JSZJK-3 3kV/√3 (1.73kV) 3kV/√3/0.1/√3/0.1 3.6/25/40kV 3×400VA 3kV indoor three-phase anti-resonance with grounding protection
JSZJK-6 6kV/√3 (3.46kV) 6kV/√3/0.1/√3/0.1 7.2/32/60kV 3×400VA 6kV indoor three-phase anti-resonance with grounding protection
JSZJK-10 10kV/√3 (5.77kV) 10kV/√3/0.1/√3/0.1 12/42/75kV 3×400VA 10kV indoor three-phase anti-resonance with grounding protection
JDZJK Series (Indoor three-phase anti-ferromagnetic, anti-resonance with three secondary windings)
Model Type Rated Voltage Voltage Ratio Insulation Level Thermal Limit Output Application
JDZJK-3 3kV/√3 (1.73kV) 3kV/√3/0.1/√3/0.1/√3/0.1 3.6/25/40kV 3×200VA 3kV indoor dual metering + grounding protection with anti-resonance
JDZJK-6 6kV/√3 (3.46kV) 6kV/√3/0.1/√3/0.1/√3/0.1 7.2/32/60kV 3×200VA 6kV indoor dual metering + grounding protection with anti-resonance
JDZJK-10 10kV/√3 (5.77kV) 10kV/√3/0.1/√3/0.1/√3/0.1 12/42/75kV 3×200VA 10kV indoor dual metering + grounding protection with anti-resonance
Anti-Magnet Ferroresonance Suppression Feature Description Benefit
Anti-Magnet Design Special core and winding design prevents ferroresonance (iron-core magnetic resonance) Eliminates dangerous ferroresonance overvoltages in indoor systems
Ferroresonance Suppression Technology Advanced anti-magnet technology suppresses ferroresonance phenomena Protects equipment from ferroresonance-induced overvoltages
Ungrounded System Protection Prevents ferroresonance in ungrounded neutral systems Essential for indoor systems without solid grounding
Resonant Grounded System Protection Prevents ferroresonance in resonant (arc suppression coil) grounded systems Critical for indoor Petersen coil grounded networks
Overvoltage Prevention Eliminates ferroresonance-induced overvoltages (up to 3-5 times rated voltage) Protects indoor equipment from destructive overvoltages
Equipment Protection Prevents damage to transformers, cables, and switchgear from ferroresonance Extends indoor equipment life and reduces failures
System Stability Maintains stable voltage during switching operations Prevents voltage instability and oscillations in indoor systems
Switching Surge Immunity Resistant to ferroresonance triggered by switching operations Reliable operation during indoor circuit breaker operations
Ground Fault Immunity Prevents ferroresonance during single-phase ground faults Maintains indoor system stability during fault conditions
Capacitive Coupling Immunity Resistant to ferroresonance from capacitive coupling Prevents resonance from indoor cable capacitance
Proven Anti-Magnet Technology Established anti-magnet design with field-proven performance Reliable ferroresonance suppression in real-world indoor applications
3×400VA Thermal Limit Output Capacity Feature Description Benefit
3×400VA Thermal Limit Output (JSZJK Dual) 3×400VA (1200VA total) thermal limit output capacity for dual secondary configuration High capacity for indoor three-phase multiple load connections
3×200VA Thermal Limit Output (JDZJK Triple) 3×200VA (600VA total) thermal limit output capacity for triple secondary configuration Adequate capacity for dual indoor three-phase metering + grounding protection
Indoor Three-Phase High Capacity High thermal limit output capacity for indoor three-phase systems Supports extensive indoor distribution loads
Multiple Load Support Can drive numerous indoor metering devices and relays Eliminates need for multiple indoor three-phase transformers
Indoor SCADA Systems Sufficient capacity for indoor three-phase data acquisition Enables advanced indoor monitoring and control
Thermal Withstand Capability Thermal limit output ensures reliable operation under overload conditions Protects transformer during temporary overload situations
310mm Creepage Distance Feature Description Benefit
310mm Surface Creepage Distance 310mm creepage distance for enhanced insulation Reliable insulation performance in indoor environments
Enhanced Insulation Extended creepage distance improves insulation reliability Prevents surface flashover and tracking
Pollution Resistance Adequate creepage distance for polluted indoor environments Reliable operation in dusty or contaminated indoor locations
Safety Margin Generous creepage distance provides safety margin Enhanced protection against insulation breakdown
Long-Term Reliability Extended creepage distance ensures long-term insulation performance Reduces maintenance and extends service life
Model Voltage Level Installation Function Winding Configuration Accuracy Class / Combination Rated Secondary Load (VA) Thermal Limit Output (VA) Application
JSZJK-3 3kV Indoor Anti-ferromagnetic resonance Dual secondary 0.2 / 6P(3P) 3×20 / 100 3×400 High-precision three-phase anti-resonance metering + grounding protection
JSZJK-3 3kV Indoor Anti-ferromagnetic resonance Dual secondary 0.5 / 6P(3P) 3×50 / 100 3×400 Standard three-phase anti-resonance metering + grounding protection
JSZJK-3 3kV Indoor Anti-ferromagnetic resonance Dual secondary 1 / 6P(3P) 3×80 / 100 3×400 General three-phase anti-resonance monitoring + grounding protection
JSZJK-3 3kV Indoor Anti-ferromagnetic resonance Dual secondary 3 / 6P(3P) 3×150 / 100 3×400 Three-phase anti-resonance instrumentation + grounding protection
JSZJK-6 6kV Indoor Anti-ferromagnetic resonance Dual secondary 0.2 / 6P(3P) 3×20 / 100 3×400 High-precision three-phase anti-resonance metering + grounding protection
JSZJK-6 6kV Indoor Anti-ferromagnetic resonance Dual secondary 0.5 / 6P(3P) 3×50 / 100 3×400 Standard three-phase anti-resonance metering + grounding protection
JSZJK-6 6kV Indoor Anti-ferromagnetic resonance Dual secondary 1 / 6P(3P) 3×80 / 100 3×400 General three-phase anti-resonance monitoring + grounding protection
JSZJK-6 6kV Indoor Anti-ferromagnetic resonance Dual secondary 3 / 6P(3P) 3×150 / 100 3×400 Three-phase anti-resonance instrumentation + grounding protection
JSZJK-10 10kV Indoor Anti-ferromagnetic resonance Dual secondary 0.2 / 6P(3P) 3×20 / 100 3×400 High-precision three-phase anti-resonance metering + grounding protection
JSZJK-10 10kV Indoor Anti-ferromagnetic resonance Dual secondary 0.5 / 6P(3P) 3×50 / 100 3×400 Standard three-phase anti-resonance metering + grounding protection
JSZJK-10 10kV Indoor Anti-ferromagnetic resonance Dual secondary 1 / 6P(3P) 3×80 / 100 3×400 General three-phase anti-resonance monitoring + grounding protection
JSZJK-10 10kV Indoor Anti-ferromagnetic resonance Dual secondary 3 / 6P(3P) 3×150 / 100 3×400 Three-phase anti-resonance instrumentation + grounding protection
JDZJK-3 3kV Indoor Anti-ferromagnetic resonance Triple secondary 0.2 / 0.2 / 6P(3P) 3×10 / 3×10 / 100 3×200 Dual high-precision metering + grounding protection
JDZJK-3 3kV Indoor Anti-ferromagnetic resonance Triple secondary 0.2 / 0.5 / 6P(3P) 3×10 / 3×15 / 100 3×200 High-precision metering + standard monitoring + grounding protection
JDZJK-3 3kV Indoor Anti-ferromagnetic resonance Triple secondary 0.5 / 0.5 / 6P(3P) 3×20 / 3×20 / 100 3×200 Dual standard metering + grounding protection
JDZJK-6 6kV Indoor Anti-ferromagnetic resonance Triple secondary 0.2 / 0.2 / 6P(3P) 3×10 / 3×10 / 100 3×200 Dual high-precision metering + grounding protection
JDZJK-6 6kV Indoor Anti-ferromagnetic resonance Triple secondary 0.2 / 0.5 / 6P(3P) 3×10 / 3×15 / 100 3×200 High-precision metering + standard monitoring + grounding protection
JDZJK-6 6kV Indoor Anti-ferromagnetic resonance Triple secondary 0.5 / 0.5 / 6P(3P) 3×20 / 3×20 / 100 3×200 Dual standard metering + grounding protection
JDZJK-10 10kV Indoor Anti-ferromagnetic resonance Triple secondary 0.2 / 0.2 / 6P(3P) 3×10 / 3×10 / 100 3×200 Dual high-precision metering + grounding protection
JDZJK-10 10kV Indoor Anti-ferromagnetic resonance Triple secondary 0.2 / 0.5 / 6P(3P) 3×10 / 3×15 / 100 3×200 High-precision metering + standard monitoring + grounding protection
JDZJK-10 10kV Indoor Anti-ferromagnetic resonance Triple secondary 0.5 / 0.5 / 6P(3P) 3×20 / 3×20 / 100 3×200 Dual standard metering + grounding protection
Ferroresonance Hazard Description Anti-Magnet Solution
Overvoltage (3-5x Rated) Ferroresonance can cause overvoltages 3-5 times rated voltage Anti-magnet design eliminates overvoltage risk
Equipment Damage Destroys transformers, cables, surge arresters, and switchgear Protects expensive indoor equipment from ferroresonance damage
Insulation Breakdown Overvoltages cause insulation breakdown and failures Prevents insulation failures and indoor system outages
Fire Hazard Ferroresonance can cause fires in transformers and cables Eliminates fire risk from ferroresonance in indoor locations
System Instability Causes voltage oscillations and system instability Maintains stable voltage and indoor system operation
Switching Operation Risk Triggered by circuit breaker switching operations Safe switching operations without ferroresonance in indoor systems
Ground Fault Risk Single-phase ground faults can trigger ferroresonance Prevents ferroresonance during indoor ground fault conditions
Ungrounded System Vulnerability Ungrounded systems highly susceptible to ferroresonance Essential protection for indoor ungrounded neutral systems
Resonant Grounded System Vulnerability Petersen coil systems prone to ferroresonance Critical for indoor arc suppression coil grounded networks
Indoor Three-Phase Anti-Magnet Anti-Resonance Application Scenario Recommended Model Key Advantage Typical Installation
Indoor Ungrounded Systems JSZJK-3/6/10 Anti-magnet ferroresonance suppression for ungrounded neutral systems Indoor substations with ungrounded neutrals
Indoor Resonant Grounded Systems JSZJK-3/6/10 Anti-resonance for Petersen coil (arc suppression coil) systems Indoor networks with arc suppression coils
Indoor Substations JSZJK-3/6/10 3×400VA thermal output + anti-magnet anti-resonance Indoor distribution substations
Indoor Switchgear JSZJK-3/6/10 Anti-magnet design for indoor metal-clad switchgear Indoor GIS, AIS, metal-clad switchgear
Indoor Cable Networks JSZJK-3/6/10 Prevents ferroresonance from indoor cable capacitance Indoor cable distribution systems
Indoor Dual Metering + Grounding Protection JDZJK-3/6/10 Triple secondary for dual metering + grounding protection + anti-resonance Indoor billing + monitoring + protection applications
Indoor High-Capacity Applications JSZJK-3/6/10 3×400VA thermal limit output for extensive indoor loads Indoor applications with extensive load requirements
Indoor 310mm Creepage Applications JSZJK-3/6/10 310mm creepage distance for polluted indoor environments Indoor polluted or contaminated locations
Feature JSZJK-3/6/10 (Indoor Anti-Magnet Anti-Resonance) JSZWK-3/6/10 (Outdoor Anti-Resonance) JSZW-3/6/10 (Indoor Three-Phase)
Installation Type Indoor Outdoor Indoor
Anti-Resonance Yes (anti-magnet ferroresonance suppression) Yes (ferroresonance suppression) No
Anti-Magnet Technology Yes No No
Thermal Limit Output 3×400VA (dual), 3×200VA (triple) 1000-1500VA 600VA (dual), 450/450VA (triple)
Creepage Distance 310mm Standard outdoor Standard indoor
Key Advantage Anti-magnet + anti-resonance + 3×400VA output + 310mm creepage Outdoor + anti-resonance + 1500VA output Indoor three-phase + grounding protection + 600VA output
Typical Application Indoor ungrounded systems, indoor resonant grounded systems Outdoor ungrounded systems, outdoor resonant grounded systems Indoor substations, indoor switchgear

Let The World Know About Bepto

Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.

Application

ANYTHING YOU COULDN’T FIND?
Talk With Our Sales

Bepto focuses on the global market and provides our clients with products suitable for the local market:

SEND US AN EMAIL
Contact Us

Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.

Form Contact 2
Bepto Logo red
Get More Benefits Since Submit The Info Form
Form Contact