JDZX11-15/20 Indoor Single-Phase Voltage Transformer: 15kV/20kV, indoor single-phase epoxy resin casting, 15kV-20kV/√3/100V/√3+100V/3 or 100V/√3+100V/√3+100V/3 ratio, dual/triple secondary winding, grounding protection, 0.2/0.5/1/6P accuracy class, 18-24/55-65/105-125kV insulation, 400VA max output, compact design, 50-60Hz, GB1207 IEC60044-2.

Applications:

Advanced JDZX11-15/20 indoor single-phase voltage transformer featuring epoxy resin casting, conforming to GB1207 and IEC60044-2 standards, two voltage levels (15kV, 20kV), rated insulation levels 18/55/105kV and 24/65/125kV, rated frequency 50Hz or 60Hz, designed for indoor single-phase high voltage power systems, dual secondary configuration with 100V/√3 measuring winding plus 100V/3 residual voltage winding, or triple secondary with dual 100V/√3 measuring windings plus 100V/3 residual voltage winding for comprehensive voltage measurement and grounding protection.

Superior high output capacity with 400VA maximum output for dual secondary configuration and 300/300VA for triple secondary supports indoor multiple load connections, accuracy classes 0.2/0.5/1/6P available for various metering and protection requirements, compact single-phase design suitable for indoor substations, indoor switchgear, and metal-clad equipment requiring reliable single-phase high voltage measurement with grounding protection, three units required for complete three-phase system monitoring.

Specifications

JDZX11-15/20 Indoor Single-Phase Voltage Transformer 15kV/20kV Epoxy Resin Casting PT - 100V/√3+100V/3 Dual/Triple Secondary Grounding Protection 0.2/0.5/1/6P Class 400VA Max Output 24/65/125kV Insulation GB1207

Features

JDZX11-15/20 Indoor Single-Phase Voltage Transformer Specifications Parameter Unit
Brand Bepto Insulation Systems
Model Number JDZX11-15, JDZX11-20
Category Switchgear & HV PT (High Voltage Potential Transformer)
Product Type 15kV/20kV Indoor Single-Phase Epoxy Resin Casting Voltage Transformer with Dual/Triple Secondary Winding, Grounding Protection, 0.2/0.5/1/6P Accuracy Class, 18-24/55-65/105-125kV Insulation, 400VA Maximum Output for Indoor Single-Phase High Voltage & Energy Measurement and Grounding Protection
Core Technology Indoor Single-Phase Epoxy Resin Casting Design + 15kV/20kV High Voltage + GB1207 and IEC60044-2 Standards Compliant + Rated Insulation Levels (18/55/105kV, 24/65/125kV) + Rated Frequency 50Hz or 60Hz + Phase-to-Ground Voltage Ratio (15kV-20kV/√3/100V/√3+100V/3 or 100V/√3+100V/√3+100V/3) + Dual/Triple Secondary Winding Configuration + Accuracy Classes (0.2, 0.5, 1, 6P) + Rated Secondary Load 15-150VA + Maximum Output 300-400VA + Compact Single-Phase Design + Proven Epoxy Resin Technology
Power (Voltage) 15kV / 20kV
Installation Type Indoor
Phase Single Phase (Three Units Required for Three-Phase System)
Rated Voltage (JDZX11-15) 15kV/√3 (8.66kV) per phase
Rated Voltage (JDZX11-20) 20kV/√3 (11.55kV) per phase
Voltage Ratio (Dual JDZX11-15) 15000/√3/100/√3 + 100/3 V
Voltage Ratio (Dual JDZX11-20) 20000/√3/100/√3 + 100/3 V
Voltage Ratio (Triple JDZX11-15) 15000/√3/100/√3 + 100/√3 + 100/3 V
Voltage Ratio (Triple JDZX11-20) 20000/√3/100/√3 + 100/√3 + 100/3 V
Secondary Measuring Winding 1 100V/√3 (57.7V) V
Secondary Measuring Winding 2 (Triple) 100V/√3 (57.7V) V
Residual Voltage Winding 100V/3 (33.3V) V
Rated Frequency 50Hz or 60Hz Hz
Accuracy Classes 0.2, 0.5, 1, 6P
Insulation Level (JDZX11-15) 18/55/105 kV
Insulation Level (JDZX11-20) 24/65/125 kV
Max Output (Dual Secondary) 400 VA
Max Output (Triple Secondary) 300/300 VA
Rated Secondary Load (0.2 Class) 30 VA
Rated Secondary Load (0.5 Class) 80 VA
Rated Secondary Load (1 Class) 150 VA
Rated Secondary Load (6P Class) 100 VA
Rated Secondary Load (0.2/0.2 Triple) 15/15 VA
Rated Secondary Load (0.2/0.5 Triple) 20/20 VA
Rated Secondary Load (0.5/0.5 Triple) 30/30 VA
Insulation Type Indoor Epoxy Resin Casting
Structure Type Indoor Single-Phase Epoxy Resin Casting
Voltage Level High Voltage (15kV/20kV)
Standards Compliance GB1207 and IEC60044-2
FOB Port Ningbo/Shanghai
Terms of Payment Western Union, T/T, Paypal
15kV/20kV High Voltage Yes (15kV/20kV Rated Voltage)
Indoor Single-Phase Yes (Indoor Single-Phase Configuration)
Indoor Epoxy Resin Casting Yes (Indoor Epoxy Resin Casting Insulation)
400VA Max Output Yes (400VA Maximum Output for Dual Secondary)
300/300VA Triple Output Yes (300/300VA Maximum Output for Triple Secondary)
100V/√3+100V/3 Ratio Yes (Phase-to-Ground Measurement + Residual Voltage)
Dual Secondary Winding Yes (Dual Secondary Configuration)
Triple Secondary Winding Yes (Triple Secondary Configuration)
Grounding Protection Yes (100V/3 Residual Voltage Winding)
50Hz or 60Hz Yes (Rated Frequency 50Hz or 60Hz)
GB1207 Compliant Yes (In Accordance with GB1207 Standard)
IEC60044-2 Compliant Yes (In Accordance with IEC60044-2 Standard)
18-24/55-65/105-125kV Insulation Yes (Rated Insulation Levels)
0.2 Accuracy Class Yes (0.2 Metering Accuracy Class Available)
0.5 Accuracy Class Yes (0.5 Metering Accuracy Class Available)
1 Accuracy Class Yes (1 Monitoring Accuracy Class Available)
6P Protection Class Yes (6P Protection Accuracy Class Available)
Compact Single-Phase Design Yes (Compact Single-Phase Unit)
Flexible Secondary Configuration Yes (Dual or Triple Secondary Options)
Model Voltage Level Insulation Level Secondary Configuration Max Output Application
JDZX11-15 (Dual) 15kV/√3 (8.66kV) 18/55/105kV 100V/√3 + 100V/3 400VA 15kV indoor single-phase measurement + grounding protection with high output
JDZX11-20 (Dual) 20kV/√3 (11.55kV) 24/65/125kV 100V/√3 + 100V/3 400VA 20kV indoor single-phase measurement + grounding protection with high output
JDZX11-15 (Triple) 15kV/√3 (8.66kV) 18/55/105kV 100V/√3 + 100V/√3 + 100V/3 300/300VA 15kV indoor dual metering + grounding protection with independent measuring circuits
JDZX11-20 (Triple) 20kV/√3 (11.55kV) 24/65/125kV 100V/√3 + 100V/√3 + 100V/3 300/300VA 20kV indoor dual metering + grounding protection with independent measuring circuits
Model Voltage Level Installation Phase Type Winding Configuration Accuracy Class / Combination Rated Secondary Load (VA) Max Output (VA) Application
JDZX11-15 15kV Indoor Single-phase Dual secondary 0.2 30 400 High-precision indoor single-phase revenue metering
JDZX11-15 15kV Indoor Single-phase Dual secondary 0.5 80 400 Standard indoor single-phase metering and monitoring
JDZX11-15 15kV Indoor Single-phase Dual secondary 1 150 400 General indoor single-phase voltage monitoring
JDZX11-15 15kV Indoor Single-phase Dual secondary 6P 100 400 Indoor single-phase relay protection and grounding protection
JDZX11-20 20kV Indoor Single-phase Dual secondary 0.2 30 400 High-precision indoor single-phase revenue metering
JDZX11-20 20kV Indoor Single-phase Dual secondary 0.5 80 400 Standard indoor single-phase metering and monitoring
JDZX11-20 20kV Indoor Single-phase Dual secondary 1 150 400 General indoor single-phase voltage monitoring
JDZX11-20 20kV Indoor Single-phase Dual secondary 6P 100 400 Indoor single-phase relay protection and grounding protection
JDZX11-15 15kV Indoor Single-phase Triple secondary 0.2 / 0.2 15 / 15 300 / 300 Dual high-precision indoor single-phase metering
JDZX11-15 15kV Indoor Single-phase Triple secondary 0.2 / 0.5 20 / 20 300 / 300 High-precision metering + standard monitoring
JDZX11-15 15kV Indoor Single-phase Triple secondary 0.5 / 0.5 30 / 30 300 / 300 Dual standard indoor single-phase metering
JDZX11-20 20kV Indoor Single-phase Triple secondary 0.2 / 0.2 15 / 15 300 / 300 Dual high-precision indoor single-phase metering
JDZX11-20 20kV Indoor Single-phase Triple secondary 0.2 / 0.5 20 / 20 300 / 300 High-precision metering + standard monitoring
JDZX11-20 20kV Indoor Single-phase Triple secondary 0.5 / 0.5 30 / 30 300 / 300 Dual standard indoor single-phase metering
400VA Maximum Output Capacity Feature Description Benefit
400VA Maximum Output (Dual) 400VA maximum output capacity for dual secondary configuration High output capacity for indoor single-phase 15kV/20kV high voltage transformers
High Capacity Metering Adequate capacity for indoor multiple load connections Supports multiple metering devices, relays, and monitoring equipment
Indoor High Voltage Application Maximum output capacity for indoor single-phase 15kV/20kV systems Adequate capacity for high voltage indoor distribution loads
Multiple Load Support Can drive multiple indoor metering devices and relays Eliminates need for additional transformers
Indoor SCADA Systems Sufficient capacity for indoor single-phase data acquisition Enables advanced indoor monitoring and control
300/300VA Triple Secondary Output Feature Description Benefit
300/300VA Dual Measuring Output 300VA output for each of two independent measuring windings High capacity for dual independent metering circuits
Independent Metering Circuits Two separate 100V/√3 measuring windings Enables independent billing and monitoring metering
Dual Metering Application Supports dual metering for separate customers or applications Ideal for split metering or redundant metering systems
Grounding Protection Additional 100V/3 residual voltage winding Comprehensive ground fault detection with dual metering
15kV/20kV High Voltage Feature Description Benefit
15kV High Voltage Level 15kV/√3 (8.66kV) rated voltage per phase Suitable for 15kV indoor high voltage distribution systems
20kV High Voltage Level 20kV/√3 (11.55kV) rated voltage per phase Suitable for 20kV indoor high voltage distribution systems
18/55/105kV Insulation (15kV) High insulation level for 15kV systems Reliable operation with adequate safety margin
24/65/125kV Insulation (20kV) High insulation level for 20kV systems Reliable operation with adequate safety margin
High Voltage Indoor Application Designed for indoor high voltage environments Safe reliable operation in indoor high voltage installations
Indoor Single-Phase 15kV/20kV Application Scenario Recommended Model Key Advantage Typical Installation
Indoor 15kV Substations JDZX11-15 (Dual) 400VA high output + grounding protection Indoor 15kV distribution substations (three units)
Indoor 20kV Substations JDZX11-20 (Dual) 400VA high output + grounding protection Indoor 20kV distribution substations (three units)
Indoor 15kV Switchgear JDZX11-15 (Dual) 400VA output for extensive load connections Indoor 15kV metal-clad switchgear (three units)
Indoor 20kV Switchgear JDZX11-20 (Dual) 400VA output for extensive load connections Indoor 20kV metal-clad switchgear (three units)
Indoor 15kV Dual Metering JDZX11-15 (Triple) Triple secondary for dual independent metering + grounding protection Indoor 15kV dual billing or redundant metering (three units)
Indoor 20kV Dual Metering JDZX11-20 (Triple) Triple secondary for dual independent metering + grounding protection Indoor 20kV dual billing or redundant metering (three units)
Indoor 15kV Energy Measurement JDZX11-15 (0.2 class) High-precision 0.2 class + 400VA output Indoor 15kV revenue metering systems (three units)
Indoor 20kV Energy Measurement JDZX11-20 (0.2 class) High-precision 0.2 class + 400VA output Indoor 20kV revenue metering systems (three units)
Feature JDZX11-15/20 (15kV/20kV Indoor) JDZX11-10 (10kV Indoor) JDZX9-35 (35kV Indoor)
Voltage Level 15kV/20kV (high voltage) 10kV (medium voltage) 35kV (high voltage)
Insulation Level 18-24/55-65/105-125kV 12/42/75kV 40.5/95/185kV
Maximum Output (Dual) 400VA 600VA 1000VA
Maximum Output (Triple) 300/300VA 300/300VA 500/500VA
Key Advantage 15kV/20kV high voltage + 400VA output + dual/triple options 10kV + 600VA highest output + dual/triple options 35kV highest voltage + 1000VA ultra-high output + dual/triple options
Typical Application Indoor 15kV/20kV substations, switchgear Indoor 10kV substations, switchgear Indoor 35kV substations, switchgear
Feature JDZX11-15/20 (15kV/20kV Indoor Single-Phase) JDZW-35 (35kV Outdoor Single-Phase) JLSZY-35 (35kV Outdoor Combined CT+PT)
Voltage Level 15kV/20kV 35kV 35kV
Installation Type Indoor Outdoor Outdoor
Product Type Single-phase PT Single-phase PT Combined CT + PT metering unit
Maximum Output 400VA (dual), 300/300VA (triple) 1000VA 350VA (PT), 10-15VA (CT)
Key Advantage 15kV/20kV indoor + 400VA output + dual/triple options 35kV outdoor + 1000VA ultra-high output + hermetically sealed 35kV outdoor combined CT+PT + energy metering box + anti-tamper
Typical Application Indoor 15kV/20kV substations, switchgear Outdoor 35kV substations, overhead lines Outdoor 35kV rural substations, energy metering

Let The World Know About Bepto

Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.

Application

ANYTHING YOU COULDN’T FIND?
Talk With Our Sales

Bepto focuses on the global market and provides our clients with products suitable for the local market:

SEND US AN EMAIL
Contact Us

Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.

Form Contact 2
Bepto Logo red
Get More Benefits Since Submit The Info Form
Form Contact