JLSZY-6/10W Outdoor Dry Type Combined CT PT Metering Box 6kV/10kV Three-Phase High Voltage – Multi-Tap 7.5-1000A 3×400VA Max Output 0.2S/0.5S Class Pollution IV Epoxy Resin Casting 12/42/75kV Insulation GB17201

JLSZY-6/10W Outdoor Dry Type Combined CT PT Metering Box: 6kV/10kV, outdoor three-phase dry type epoxy resin casting, multi-tap current transformer 7.5-1000A, 6kV-10kV/100V voltage ratio, 0.2S/0.5S accuracy class, pollution class IV, 3×400VA max output, 7.2-12/32-42/60-75kV insulation, 50-60Hz, GB17201.
JLSZV2-6/10 Outdoor Dry Type Combined CT PT Metering Box 6kV/10kV Three-Phase High Voltage – Multi-Tap 7.5-1000A 2×400VA Max Output 0.2S/0.5S Class Pollution IV Epoxy Resin Casting 12/42/75kV Insulation GB17201

JLSZV2-6/10 Outdoor Dry Type Combined CT PT Metering Box: 6kV/10kV, outdoor three-phase dry type epoxy resin casting, multi-tap current transformer 7.5-1000A, 6kV-10kV/100V voltage ratio, 0.2S/0.5S accuracy class, pollution class IV, 2×400VA max output, 7.2-12/32-42/60-75kV insulation, 50-60Hz, GB17201.
JLS-6/10/24/35 Outdoor Combined CT PT Metering Box High Voltage Power Metering Unit – Integrated Current Voltage Transformer with Watt-Hour Meter 0.2/0.5/0.2S/0.5S Class Oil-Immersed 5-300/5A 40.5/95/185kV GB17201

JLS-6/10/24/35 Outdoor Combined CT PT Metering Box: 6kV/10kV/24kV/35kV, outdoor oil-immersed combined current and voltage transformer with integrated watt-hour meter box, 5-300/5A current ratio, 3kV-35kV/100V-110V voltage ratio, 0.2/0.5/0.2S/0.5S accuracy class, 3.6-40.5/24-95/75-185kV insulation, anti-tamper design, 50-60Hz, GB17201.
JDZX12A/JDZ16-3/6/10R Indoor Elbow Type Voltage Transformer 3kV/6kV/10kV with Fuse Cutout – 200A American Elbow Plug Epoxy Resin Casting PT 1000VA Max Output 0.2/0.5/1/3 Class 12/42/75kV Insulation GB1207

JDZX12A/JDZ16-3/6/10R Indoor Elbow Type Voltage Transformer: 3kV/6kV/10kV, indoor single-phase epoxy resin casting, 200A American elbow plug connection, with fuse cutout, dual/triple secondary winding, 0.2/0.5/1/3 accuracy class, 3.6-12/23-42/40-75kV insulation, 1000VA max output, compact elbow design, 50-60Hz, GB1207 IEC60044-2.
JDZX10-3/6/10 Indoor Single-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 100V/√3+100V/3 Dual Secondary Grounding Protection 0.2/0.5/1/3/6P Class 200VA Max Output 12/42/75kV Insulation GB1207

JDZX10-3/6/10 Indoor Single-Phase Voltage Transformer: 3kV/6kV/10kV, indoor single-phase epoxy resin casting, 3kV-10kV/√3/100V/√3+100V/3 ratio, dual secondary winding, grounding protection, 0.2/0.5/1/3/6P accuracy class, 3.6-12/25-42/40-75kV insulation, 200VA max output, compact design, 50-60Hz, GB1207 IEC60044-2.
JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – Anti-Magnet Ferroresonance Suppression 100V/√3+100V/√3 Triple Secondary 0.2/0.5/1/3/6P Class 3×400VA GB1207

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, anti-magnet ferroresonance suppression, 3kV-10kV/√3/100V/√3+100V/√3 ratio, triple secondary winding, 0.2/0.5/1/3/6P accuracy class, 3.6-12/25-42/40-75kV insulation, 3×400VA thermal limit output, 310mm creepage, 50-60Hz, GB1207 IEC60044-2.
JSZV12A-3/6/10 Indoor Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 3000/100 6000/100 10000/100 Dual Secondary 0.2/0.5/1/3 Class 600×√3 VA Ultra-High Output 12/42/75kV GB1207

JSZV12A-3/6/10 Indoor Three-Phase Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, 3000/100, 6000/100, 10000/100 phase-to-phase ratio, dual secondary winding, 0.2/0.5/1/3 accuracy class, 3.6-12/23-42/40-75kV insulation, 600×√3 VA ultra-high output, compact integrated design, 50-60Hz, GB1207 IEC60044-2.
JSZW-3/6/10 Indoor Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 100V/√3+100V/3 Triple Secondary Grounding Protection 0.2/0.5/1/3/6P Class 600VA High Output 12/42/75kV Insulation GB1207

JSZW-3/6/10 Indoor Three-Phase Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, 3kV-10kV/√3/100V/√3+100V/3 ratio, triple secondary winding, grounding protection, 0.2/0.5/1/3/6P accuracy class, 3.6-12/23-42/40-75kV insulation, 600VA max output, compact integrated design, 50-60Hz, GB1207 IEC60044-2.
JSZWK-3/6/10 Outdoor Anti-Resonance Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 100V/√3+100V Triple Secondary Ferroresonance Suppression 0.2/0.5/6P Class 1500VA High Output 12/42/75kV GB1207

JSZWK-3/6/10 Outdoor Anti-Resonance Three-Phase Voltage Transformer: 3kV/6kV/10kV, outdoor three-phase epoxy resin casting, ferroresonance suppression, 3kV-10kV/√3/100V/√3+100V ratio, triple secondary winding, 0.2/0.5/6P accuracy class, 3.6-12/25-42/40-75kV insulation, 1500VA max output, weather-resistant, 50-60Hz, GB1207 IEC60044-2.
JDZ(X)W-3/6/10(R) Outdoor Voltage Transformer Single-Phase Epoxy Resin Casting PT – 3kV/6kV/10kV 0.2/0.5/1/3/6P Class Phase-to-Ground Triple Secondary 1000VA High Output 12/42/75kV Insulation

JDZ(X)W-3/6/10(R) Outdoor Voltage Transformer Single-Phase Epoxy Resin Casting PT: 3kV/6kV/10kV, outdoor installation, phase-to-phase and phase-to-ground measurement, 3kV-10kV/√3/100V/√3+100V/3 ratio, 0.2/0.5/1/3/6P accuracy class, triple secondary winding, epoxy resin casting, 3.6-12/25-42/40-75kV insulation, 1000VA max output, 50-60Hz, GB1207 IEC60044-2.