BEGV12D/630/20S Vacuum Circuit Breaker 12kV 24kV 630A – SF6 Free GIS Upper Isolation Grounding 20kA Breaking
BEC12D/630/20 Load Break Switch 12kV 24kV 630A – SF6 Free Gas Insulated Switchgear GIS 20kA Withstand

BEC12D/630/20 Load Break Switch: SF6-free 12kV/24kV 630A for gas insulated switchgear GIS, 20kA/25kA withstand, 50kA making current, 5000 operations, automated distribution network ready.
BE36SV/630/3 SF6 Circuit Breaker 36kV 630A – Upper Isolation Switch Vacuum Interrupter Switchgear 185kV Lightning Impulse

BE36SV/630/3 SF6 Circuit Breaker: 36kV 630A upper isolation switch with vacuum interrupter for switchgear, 185kV lightning impulse, 95kV withstand, automated distribution network operation.
24kV Sensor Insulator CG5 Series 9 Models – High Voltage Current Sensors 75×190-225 85×190-225 110×190-225mm HV Switchgear GIS

CG5-24kV Sensor Insulator: 9 models high voltage current sensors 75×190-225/85×190-225/110×190-225mm, 65kV withstand voltage, 125kV impulse, epoxy resin casting for HV switchgear & GIS.
12kV Sensor Insulator CG5 Series 8 Models – Current Transducers 95×125-170mm 100×140-150mm MV Switchgear

CG5 12kV Sensor Insulator: 8 models current transducers 95×125-170mm & 100×140-150mm, professional MV switchgear detection, Bepto brand quality.
40.5KV Three-Way KYN61 Shielded Contact Box – CH3 40.5-305P/660 185kV 630-3150A Triple Position

CH3 40.5-305P/660 40.5KV Three-Way KYN61 Contact Box: Triple position design, 630-3150A high current, 185kV lightning impulse, 95kV power frequency for KYN61 multi-circuit switchgear.
40.5KV KYN61 Shielded Contact Box – CH3 40.5-303P/660 185kV Lightning 630-3150A High Current

CH3 40.5-303P/606 40.5KV KYN61 Shielded Contact Box: High current 630-3150A, 185kV lightning impulse, 95kV power frequency for KYN61 switchgear applications.
40.5KV Three-Way Shielded Contact Box – CH3 40.5-315P/606 185kV Lightning 630-2500A Triple Position

CH3 40.5-315P/606 40.5KV Three-Way Shielded Contact Box: Triple position design, 185kV lightning impulse, 95kV power frequency, 630-2500A for KYN28-12/24/61 VD4 switchgear.
40.5KV VD4 Shielded Contact Box – CH3 40.5-304P/606 185kV Lightning Impulse 630-2500A Air Insulation

CH3 40.5-304P/606 40.5KV VD4 Shielded Contact Box: 185kV lightning impulse withstand, 95kV power frequency, 630-2500A air insulation series for KYN28-12/24/61 VD4 switchgear applications.
40.5KV Medium Altitude Shielded Contact Box – CH3 40.5-308P/730 3000m 235kV Lightning Impulse 630-2500A

CH3 40.5-308P/730 40.5KV Medium Altitude Shielded Contact Box: 3000m altitude rated, 235kV lightning impulse withstand, 630-2500A air insulation series, KYN28-12/24/61 VD4 switchgear.