GW9 Outdoor HV Isolator Switch 10-20kV 400-1250A – Hookstick Type Transmission Line Non-Load Shifting Copper Aluminum Stainless Steel 20-31.5kA

GW9 Outdoor HV Isolator Switch 10-20kV 400-1250A: Hookstick type, three-phase AC 50Hz, transmission line non-load shifting, busbar maintenance, circuit breaker isolation, copper aluminum annex, stainless steel firmware, hot plating zinc base, anti-dirt resistance corrosion, 20-31.5kA withstand, 50-80kA peak.
GN30-12 Indoor Rotary Grounding Disconnector 12kV 400-3150A – Three-Phase Cabinet Mounted IEC62271-102 No-Load Transfer Switch 4s Duration

GN30-12 Indoor Rotary Grounding Disconnector 12kV 400-3150A: Three-phase AC 50/60Hz, rotary moving contact, cabinet mounted, wall through installation, IEC62271-102 compliant, no-load transfer, 12.5-40kA withstand, 31.5-100kA peak, 42kV/49kV frequency withstand, 75kV/85kV impulse.
GN24-12 Indoor HV Disconnect Switch 12kV 400A-1250A – Three-Pole Type No-Load Breaking Pollution Abatement High Altitude Electrified Display 2000 Life

GN24-12 Indoor HV Disconnect Switch 12kV 400A-1250A: Three-pole type, no-load breaking, pollution abatement type, high altitude type, electrified display, 2000 mechanical life, 20kA short-time withstand, 50kA peak withstand, porcelain insulator, 1000-3000m altitude, -30°C to +40°C.
GN19-12 Indoor High Voltage Isolation Disconnector 12kV 630A-1250A – CS6-1 Manual Mechanism Through-Wall Type MV Switchgear 2000 Mechanical Life

GN19-12 Indoor High Voltage Isolation Disconnector 12kV 630A-1250A: CS6-1 manual mechanism, through-wall type C1/C2/C3, no-load breaking, 2000 mechanical life, 20kA short-time withstand, 50kA peak withstand, porcelain insulator, live display device, anti-pollution type.
FW11-12 Air Load Break Switch 12kV 630A – Outdoor Disconnector Cutout Fuse Tropical Zone 1800m

FW11-12 Air Load Break Switch: 12kV 630A outdoor disconnector with cutout fuse, tropical zone design, rocking insulator, 1800m altitude, 0-100% humidity, vertical/horizontal mounting, 40°C max.
FW9-12 SF6 Load Break Switch 12kV 630A – Outdoor Sectionalizer Remote Control Stainless Steel 5000m

FW9-12 SF6 Load Break Switch: 12kV 630A outdoor sectionalizer, manual/electric/remote operation, electronic controller, stainless steel cabinet, 5000m altitude, -40°C to +50°C, visible open/closed status.
IACM Manually Operated Overhead Switch 36kV 400A – Air-Break Disconnector Isolate Restore 2000m IEC

IACM Manually Operated Overhead Switch: 36kV 400A air-break disconnector, isolate/restore line sections, maintenance/troubleshooting, human intervention, 2000m altitude, IEC compliant, -30°C to +40°C.
IA1CM Overhead Switch Disconnector 17.5kV 1250A – Manual Air-Break LBS Hot-Dip Galvanized NF C 64-140

IA1CM Overhead Switch Disconnector: 17.5kV 1250A manual air-break LBS, hot-dip galvanized steel, tempered glass insulators, live working, NF C 64-140 Type I, tree network, visible opening.
IACM-50A Overhead Switch Disconnector 12-36kV 1250A – Air-Break Tree Network LBS 2000m NF C 64-140

IACM-50A Overhead Switch Disconnector: 12-36kV 1250A air-break tree network LBS, end-of-line isolation, substation cluster, NF C 64-140 Type I, 2000m altitude, -30°C to +40°C.
ISAR-S Load Break Disconnector 12-36kV 1250A – Air-Break Overhead Outdoor Switch 2000m Altitude

ISAR-S Load Break Disconnector: 12-36kV 1250A air-break overhead outdoor switch, visible opening, 2000 cycles, 2000m altitude, IEC compliant, radial/ring network, -30°C to +40°C.