跳到内容
  • Home
  • Product
    • Air Insulation Series
    • Switching Devices
    • Gas Insulation Series
  • Custom Service
  • Solutions
  • About
  • Resource
    • After Sales
    • FAQS
    • Downloads
    • Certification
  • News
    • Industry News
    • Company News
  • Contact
  • English
  • Home
  • Product
    • Air Insulation Series
    • Switching Devices
    • Gas Insulation Series
  • Custom Service
  • Solutions
  • About
  • Resource
    • After Sales
    • FAQS
    • Downloads
    • Certification
  • News
    • Industry News
    • Company News
  • Contact
  • English

Product Tag: 3150A

GN30-12 Indoor Rotary Grounding Disconnector 12kV 400-3150A – Three-Phase Cabinet Mounted IEC62271-102 No-Load Transfer Switch 4s Duration

GN30-12 Indoor Rotary Grounding Disconnector 12kV 400-3150A - Three-Phase Cabinet Mounted IEC62271-102 No-Load Transfer Switch 4s Duration

GN30-12 Indoor Rotary Grounding Disconnector 12kV 400-3150A: Three-phase AC 50/60Hz, rotary moving contact, cabinet mounted, wall through installation, IEC62271-102 compliant, no-load transfer, 12.5-40kA withstand, 31.5-100kA peak, 42kV/49kV frequency withstand, 75kV/85kV impulse.

ZW32-24 Outdoor Vacuum Circuit Breaker 24kV VCB 3150A – Smart Recloser Controller Fault Isolation Distribution Automation

ZW32-24 Outdoor Vacuum Circuit Breaker 24kV VCB 3150A - Smart Recloser Controller Fault Isolation Distribution Automation

ZW32-24 Outdoor Vacuum Circuit Breaker: 24kV VCB 3150A smart recloser, controller with fault isolation, distribution automation, 40kA breaking, multiple auto reclosing, three-stage protection, electronic PT, -40°C to +40°C.

ZW32-12 Outdoor Vacuum Circuit Breaker 12kV MV VCB 4000A – Smart Recloser Controller Fault Isolation Distribution Automation

ZW32-12 Outdoor Vacuum Circuit Breaker 12kV MV VCB 4000A - Smart Recloser Controller Fault Isolation Distribution Automation

ZW32-12 Outdoor Vacuum Circuit Breaker: 12kV MV VCB 4000A smart recloser, controller with fault isolation, distribution automation, 40kA breaking, multiple auto reclosing, three-stage protection, electronic PT, -40°C to +40°C.

ZN63A-12 VS1 Vacuum Circuit Breaker 12kV/24kV 4000A – Indoor High Voltage VCB Embedded Poles KYN28A Switchgear

ZN63A-12 VS1 Vacuum Circuit Breaker 12kV-24kV 4000A - Indoor High Voltage VCB Embedded Poles KYN28A Switchgear

ZN63A-12 VS1 Vacuum Circuit Breaker: 12kV/24kV 4000A indoor high voltage VCB, embedded poles, KYN28A/XGN switchgear, solid-sealed poles, E2/M2 life, free maintenance, 40kA breaking, 10000 cycles, -15°C to +40°C.

VSG-12 Vacuum Circuit Breaker 12kV 4000A – Indoor High Voltage VCB Power Grid Switchgear 10000 Cycles

VSG-12 Vacuum Circuit Breaker 12kV 4000A - Indoor High Voltage VCB Power Grid Switchgear 10000 Cycles

VSG-12 Vacuum Circuit Breaker: 12kV 4000A indoor high voltage VCB, power grid switchgear, 10000 cycles, enclosed column, maintenance-free, 40kA breaking, E2/M2 life, frequent operation, -15°C to +40°C.

VSG-24 Vacuum Circuit Breaker 24kV 3150A – Indoor High Voltage VCB Power Grid Switchgear 10000 Cycles

VSG-24 Vacuum Circuit Breaker 24kV 3150A - Indoor High Voltage VCB Power Grid Switchgear 10000 Cycles

VSG-24 Vacuum Circuit Breaker: 24kV 3150A indoor high voltage VCB, power grid switchgear, 10000 cycles, enclosed column, maintenance-free, 40kA breaking, frequent operation, -15°C to +40°C.

HD4 SF6 Circuit Breaker 12-40.5kV 3150A – Indoor Gas Insulated Switchgear Maintenance-Free Lifetime Sealed

HD4 SF6 Circuit Breaker 12-40.5kV 3150A - Indoor Gas Insulated Switchgear Maintenance-Free Lifetime Sealed

HD4 SF6 Circuit Breaker: 12-40.5kV 3150A indoor gas insulated switchgear, lifetime sealed poles, maintenance-free, no chopping/reignition, fixed/withdrawable, 50kA breaking, -5°C to +40°C.

35kV Sensor Insulator CG5 Series 8 Models – High Current Sensors 130×320-380 145×320-380mm 95kV 185kV HV Breaker Switchgear Substation

CG5-35kV 130×360

CG5-35kV Sensor Insulator: 8 models high current sensors 130×320-380/145×320-380mm, 2000A-3150A, 95kV withstand 185kV impulse, epoxy resin for HV breaker switchgear substation.

40.5KV Three-Way KYN61 Shielded Contact Box – CH3 40.5-305P/660 185kV 630-3150A Triple Position

40.5KV Three-Way KYN61 Shielded Contact Box - CH3 40.5-305P660 185kV 630-3150A Triple Position

CH3 40.5-305P/660 40.5KV Three-Way KYN61 Contact Box: Triple position design, 630-3150A high current, 185kV lightning impulse, 95kV power frequency for KYN61 multi-circuit switchgear.

40.5KV KYN61 Shielded Contact Box – CH3 40.5-303P/660 185kV Lightning 630-3150A High Current

40.5KV KYN61 Shielded Contact Box - CH3 40.5-303P660 185kV Lightning 630-3150A High Current

CH3 40.5-303P/606 40.5KV KYN61 Shielded Contact Box: High current 630-3150A, 185kV lightning impulse, 95kV power frequency for KYN61 switchgear applications.

Next →

Leading electrical insulation solutions provider with international certifications, serving automotive, commercial, residential, and industrial sectors. Partnering with global brands, delivering reliable services worldwide.

Facebook-f Twitter

Quick Links

  • Custom Service
  • Air Insulation Series
  • Gas Insulation Series
  • Switching Devices
  • Instrument Transformer
  • Custom Service
  • Air Insulation Series
  • Gas Insulation Series
  • Switching Devices
  • Instrument Transformer

About Company

  • News
  • About
  • Contact
  • After Sales
  • Downloads
  • Certification
  • Company FAQ
  • News
  • About
  • Contact
  • After Sales
  • Downloads
  • Certification
  • Company FAQ

Get In Touch

  • Business Department (Zhejiang):
    Xuezhai Industrial Zone, Liushi Town, Yueqing, Zhejiang, 325604, China
  • Factory (Jiangsu):
    Building 4, No. 118 Youyi North Road, Kunshan, Suzhou, Jiangsu, 215300, China
  • Email: insulator@bepto.com
  • Phone/WhatsApp: +86 136 5077 7767
  • Privacy Policy
  • Terms & Conditions
  • Sitemap
  • Privacy Policy
  • Terms & Conditions
  • Sitemap

© 2025 Bepto Insulation Systems | A Bepto Product Line. All Rights Reserved.