SC6 LBSkit SF6 Load Break Switch 7.2-36kV 630A – MV Switchgear Sealed for Life Compact Modular

SC6 LBSkit SF6 Load Break Switch: 7.2-36kV 630A MV switchgear, sealed for life SF6 technology, compact modular design, reduced maintenance, 35 years experience, 2.7M units installed worldwide.
FZW32-24 Vacuum Load Break Switch 24kV 1250A – Outdoor High Voltage Disconnect 10000 Cycles Frequent Operation

FZW32-24 Vacuum Load Break Switch: 24kV 1250A outdoor high voltage disconnect, 10000 cycles, frequent operation, 1600kVA transformer, strong arcing, no pollution, -30°C to +40°C, 1000m altitude.
FKW18-12 Overhead Load Break Switch 12kV 630A – Outdoor Compressed Gas Arc Extinguishing 10000 Cycles

FKW18-12 Overhead Load Break Switch: 12kV 630A outdoor LBS, compressed gas arc extinguishing, 10000 mechanical cycles, high fracture insulation, 1000m altitude, -30°C to +40°C, simple structure.
FW11-12 Air Load Break Switch 12kV 630A – Outdoor Disconnector Cutout Fuse Tropical Zone 1800m

FW11-12 Air Load Break Switch: 12kV 630A outdoor disconnector with cutout fuse, tropical zone design, rocking insulator, 1800m altitude, 0-100% humidity, vertical/horizontal mounting, 40°C max.
FW9-12 SF6 Load Break Switch 12kV 630A – Outdoor Sectionalizer Remote Control Stainless Steel 5000m

FW9-12 SF6 Load Break Switch: 12kV 630A outdoor sectionalizer, manual/electric/remote operation, electronic controller, stainless steel cabinet, 5000m altitude, -40°C to +50°C, visible open/closed status.
FKW-36 Outdoor Line Disconnector 36kV 630A – Load Break Switch Gas Arc Extinguishing 1000m Altitude

FKW-36 Outdoor Line Disconnector 36kV 630A – Load Break Switch Gas Arc Extinguishing 1000m Altitude
IACM Manually Operated Overhead Switch 36kV 400A – Air-Break Disconnector Isolate Restore 2000m IEC

IACM Manually Operated Overhead Switch: 36kV 400A air-break disconnector, isolate/restore line sections, maintenance/troubleshooting, human intervention, 2000m altitude, IEC compliant, -30°C to +40°C.
IA1CM Overhead Switch Disconnector 17.5kV 1250A – Manual Air-Break LBS Hot-Dip Galvanized NF C 64-140

IA1CM Overhead Switch Disconnector: 17.5kV 1250A manual air-break LBS, hot-dip galvanized steel, tempered glass insulators, live working, NF C 64-140 Type I, tree network, visible opening.
IACM-50A Overhead Switch Disconnector 12-36kV 1250A – Air-Break Tree Network LBS 2000m NF C 64-140

IACM-50A Overhead Switch Disconnector: 12-36kV 1250A air-break tree network LBS, end-of-line isolation, substation cluster, NF C 64-140 Type I, 2000m altitude, -30°C to +40°C.
ISAR-S Load Break Disconnector 12-36kV 1250A – Air-Break Overhead Outdoor Switch 2000m Altitude

ISAR-S Load Break Disconnector: 12-36kV 1250A air-break overhead outdoor switch, visible opening, 2000 cycles, 2000m altitude, IEC compliant, radial/ring network, -30°C to +40°C.