LZZBW-10 Support Type Current Transformer 10kV Outdoor Full-Enclosed CT – 10-1500A Multi-Ratio 0.2S/0.5/10P10/10P20 Class Swiss CIBA Epoxy Resin 12/42/75kV Pollution Class IV

LZZBW-10 Support Type Current Transformer 10kV Outdoor Full-Enclosed CT: 10-1500A primary current, 0.2S/0.5/10P10/10P20 accuracy class, multi-ratio configuration, Swiss CIBA CW5837 epoxy resin, 12/42/75kV insulation level, pollution class IV, 10-20VA burden, arc/UV/aging resistant, 5A/1A secondary, 50-60Hz, GB1208 IEC60044-1.
LJW-10/35 LJWD-10/35 Current Transformer Indoor Outdoor Dual-Use Oil-Immersed CT – 10kV/35kV 5-600A 0.2/0.5/1/3D Class Steel Tank 75× Thermal 187.5× Dynamic 40.5/95/185kV GB1208 IEC60044-1

LJW-10/35 LJWD-10/35 Current Transformer Indoor Outdoor Dual-Use Oil-Immersed CT: 10kV/35kV, 5-600A primary current, 0.2/0.5/1/3D accuracy class, steel tank oil-immersed, 75× thermal stability, 187.5× dynamic stability, 40.5/95/185kV insulation, 10-50VA burden, 5A secondary, 50Hz, GB1208 IEC60044-1.
LZZJ-10Q Current Transformer 10kV Indoor CT – 5-1600A Dual Winding 0.2S/0.5/10P10 Class Epoxy Resin Casting 12/42/75kV Insulation 10-30VA Burden 5A/1A Secondary GB1208 IEC60044-1

LZZJ-10Q Current Transformer 10kV Indoor CT: 5-1600A primary current, 0.2S/0.2/0.5/10P10 accuracy class, dual winding configuration, 12/42/75kV insulation level, 10-30VA burden capacity, 1s thermal current 0.75-80kA, rated dynamic current 1.87-130kA, 5A/1A secondary, 50-60Hz, epoxy resin casting, GB1208 IEC60044-1.
LZZBJ18-10/185h/4 Current Transformer 10kV Support Type CT – 10-4000A 0.2S/0.5/10P Class 250×In Thermal 625×In Dynamic Quad Winding Vacuum Casting 12/42/75kV Epoxy Resin GB1208 IEC60044-1

LZZBJ18-10/185h/4 Current Transformer 10kV Support Type CT: 10-4000A primary current, 0.2S/0.5/10P10/10P15/10P20 accuracy class, 250×In thermal capacity for 50-100A, 625×In dynamic current, 12/42/75kV insulation level, quad winding, vacuum casting, 10-50VA burden, 5A/1A secondary, 50-60Hz, GB1208 IEC60044-1.
LZX-10 Current Transformer 10kV Indoor CT – 5-1000A 0.2S/0.5S/10P Class 100×In Thermal 250×In Dynamic 12/42/75kV Epoxy Resin GB1208 IEC60044-1

LZX-10 Current Transformer 10kV Indoor CT: 5-1000A primary current, 0.2S/0.5S/10P10/10P15 accuracy class, 100×In thermal capacity for 50-400A, 250×In dynamic current, 12/42/75kV insulation level, 10-15VA burden, 5A/1A secondary, 50/60Hz, GB1208 IEC60044-1 compliant, metering & protection.
LZJ8-10 Current Transformer 10kV Indoor HV CT – 5-1000A 0.2S/0.5S/10P Class 100×In Thermal 250×In Dynamic 12/42/75kV Epoxy Resin GB1208 IEC60044-1

LZJ8-10 Current Transformer 10kV Indoor HV CT: 5-1000A primary current, 0.2S/0.5S/10P10/10P15 accuracy class, 100×In thermal capacity for 50-400A, 250×In dynamic current, 12/42/75kV insulation level, 10-15VA burden, 5A/1A secondary, 50/60Hz, GB1208 IEC60044-1 compliant, metering & protection.
LQJ-10 Current Transformer 10kV Indoor High Voltage CT – 5-600A 0.2S/0.5S/10P Class 100×In Thermal 250×In Dynamic 12/42/75kV Epoxy Resin GB1208 IEC60044-1

LQJ-10 Current Transformer 10kV Indoor High Voltage CT: 5-600A primary current, 0.2S/0.5S/10P10 accuracy class, 100×In thermal capacity for 75-200A, 250×In dynamic current, 12/42/75kV insulation level, 10-15VA burden, 5A/1A secondary, 50/60Hz, GB1208 IEC60044-1 compliant, metering & protection.
LMZB3-10(Q) LMZBJ9-10 Current Transformer 10kV Indoor Epoxy Resin – 300-6000A 0.2S/0.5S/10P15 Class High Current Dual Winding 12/42/75kV GB1208 IEC60044-1

LMZB3-10(Q) LMZBJ9-10 Current Transformer 10kV Indoor Epoxy Resin: 300-6000A high current range, dual winding configuration, 0.2S/0.5S/10P15 accuracy class, 12/42/75kV insulation level, 15-30VA rated output, 5A/1A secondary, 50/60Hz, GB1208 IEC60044-1 compliant, high current metering & protection.
LFS-10Q LFSQ-10Q Current Transformer 10kV Indoor Epoxy Resin – 5-1600A 0.2S/0.5S/10P Class 100×In Thermal 250×In Dynamic 12/42/75kV Dual Series GB1208 IEC60044-1

LFS-10Q LFSQ-10Q Current Transformer 10kV Indoor Epoxy Resin: Dual series 5-1600A primary current, 0.2S/0.5S/10P10/10P15 accuracy class, 100×In thermal capacity for LFS-10Q 5-200A, 250×In dynamic current, 12/42/75kV insulation, 5A/1A secondary, 50/60Hz, GB1208 IEC60044-1, metering & protection.
LDJ-10(Q)/210 Current Transformer 10kV Indoor Epoxy Resin – 5-1250A Multi-Winding 0.2S/0.5S/5P10 Class 12/42/75kV Insulation Compact Design GB1208 IEC60044-1

LDJ-10(Q)/210 Current Transformer 10kV Indoor Epoxy Resin: 5-1250A primary current, multi-winding configuration, 0.2S/0.5S/5P10 accuracy class, 12/42/75kV insulation level, compact design, 10-25VA burden capacity, 5A/1A secondary, 50/60Hz, GB1208 IEC60044-1 compliant, metering & relay protection.