JSZW-3/6/10 Indoor Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 100V/√3+100V/3 Triple Secondary Grounding Protection 0.2/0.5/1/3/6P Class 600VA High Output 12/42/75kV Insulation GB1207

JSZW-3 6 10 Indoor Three-Phase Voltage Transformer 3kV 6kV 10kV Epoxy Resin Casting PT

JSZW-3/6/10 Indoor Three-Phase Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, 3kV-10kV/√3/100V/√3+100V/3 ratio, triple secondary winding, grounding protection, 0.2/0.5/1/3/6P accuracy class, 3.6-12/23-42/40-75kV insulation, 600VA max output, compact integrated design, 50-60Hz, GB1207 IEC60044-2.

JSZWK-3/6/10 Outdoor Anti-Resonance Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 100V/√3+100V Triple Secondary Ferroresonance Suppression 0.2/0.5/6P Class 1500VA High Output 12/42/75kV GB1207

JSZWK-3/6/10 Outdoor Anti-Resonance Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT - 100V/√3+100V Triple Secondary Ferroresonance Suppression 0.2/0.5/6P Class 1500VA High Output 12/42/75kV GB1207

JSZWK-3/6/10 Outdoor Anti-Resonance Three-Phase Voltage Transformer: 3kV/6kV/10kV, outdoor three-phase epoxy resin casting, ferroresonance suppression, 3kV-10kV/√3/100V/√3+100V ratio, triple secondary winding, 0.2/0.5/6P accuracy class, 3.6-12/25-42/40-75kV insulation, 1500VA max output, weather-resistant, 50-60Hz, GB1207 IEC60044-2.

JDZ(X)W-3/6/10(R) Outdoor Voltage Transformer Single-Phase Epoxy Resin Casting PT – 3kV/6kV/10kV 0.2/0.5/1/3/6P Class Phase-to-Ground Triple Secondary 1000VA High Output 12/42/75kV Insulation

JDZ(X)W-3 6 10(R) Outdoor Voltage Transformer Single-Phase Epoxy Resin Casting PT - 3kV 6kV 10kV 0.2 0.5 1 3 6P Class Phase-to-Ground Triple Secondary 1000VA High Output 12 42 75kV Insulation

JDZ(X)W-3/6/10(R) Outdoor Voltage Transformer Single-Phase Epoxy Resin Casting PT: 3kV/6kV/10kV, outdoor installation, phase-to-phase and phase-to-ground measurement, 3kV-10kV/√3/100V/√3+100V/3 ratio, 0.2/0.5/1/3/6P accuracy class, triple secondary winding, epoxy resin casting, 3.6-12/25-42/40-75kV insulation, 1000VA max output, 50-60Hz, GB1207 IEC60044-2.

JDZ20 Voltage Transformer Indoor Single-Phase Semi-Closed Epoxy Resin Casting PT – 6kV/10kV Fully Insulated ZW8 Vacuum Circuit Breaker Compatible 12/42/75kV Insulation Compact Design

JDZ20 Voltage Transformer Indoor Single-Phase Semi-Closed Epoxy Resin Casting PT - 6kV 10kV Fully Insulated ZW8 Vacuum Circuit Breaker Compatible 12 42 75kV Insulation Compact Design

JDZ20-6/10 Voltage Transformer Indoor Single-Phase Semi-Closed Epoxy Resin Casting PT: 6kV/10kV, fully insulated design, ZW8 outdoor vacuum circuit breaker compatible, 6000/10000V/100V ratio, epoxy resin casting semi-closed construction, 7.2-12/32-42/60-75kV insulation level, compact lightweight design, 50-60Hz, GB1207 IEC60044-2.

JDZ(X)9-3/6/10Q(G) Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT – 3kV/6kV/10kV 0.2/0.5/1/3/6P Class Phase-to-Ground Dual Secondary 12/42/75kV Insulation 500-600VA Max Output GB1207 IEC60044-2

JDZ(X)9-3 6 10Q(G) Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT - 3kV 6kV 10kV 0.2 0.5 1 3 6P Class Phase-to-Ground Dual Secondary 12 42 75kV Insulation 500-600VA Max Output

JDZ(X)9-3/6/10Q(G) Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT: 3kV/6kV/10kV, phase-to-phase and phase-to-ground measurement, 3kV/√3-10kV/√3/100V/√3+100V/3 ratio, 0.2/0.5/1/3/6P accuracy class, dual secondary winding option, epoxy resin casting insulation, 3.6-12/25-42/40-75kV insulation level, 30-500VA burden, 500-600VA max output, 50-60Hz, GB1207 IEC60044-2.

JDZ9-3/6/10R3 Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT – 3kV/6kV/10kV 0.2/0.5/1/3 Class Dual Secondary 10kV/100V/220V Ratio 12/42/75kV Insulation 600VA Max Output GB1207 IEC60044-2

JDZ9-3 6 10R3 Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT - 3kV 6kV 10kV 0.2 0.5 1 3 Class Dual Secondary 10kV 100V 220V Ratio 12 42 75kV Insulation 600VA Max Output

JDZ9-3/6/10R3 Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT: 3kV/6kV/10kV, 3000/6000/10000V/100V ratio, 10kV/100V/220V dual voltage ratio, 0.2/0.5/1/3 accuracy class, dual secondary winding option, epoxy resin casting insulation, 3.6-12/23-42/40-75kV insulation level, 30-250VA burden, 600VA max output, 50-60Hz, GB1207 IEC60044-2.

JDZ-3/6/10kV Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT – 3kV/6kV/10kV 0.2/0.5/1/3/6P Class Dual Secondary Winding 12/42/75kV Insulation 200-500VA Max Output GB1207 IEC60044-2

JDZ-3 6 10kV Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT - 3kV 6kV 10kV 0.2 0.5 1 3 6P Class Dual Secondary Winding 12 42 75kV Insulation 200-500VA Max Output

JDZ-3/6/10kV Voltage Transformer Indoor Single-Phase Epoxy Resin Casting PT: 3kV/6kV/10kV, 3000/6000/10000V/100V ratio, 0.2/0.5/1/3/6P accuracy class, dual secondary winding option, epoxy resin casting insulation, 3.6-12/25-42/40-75kV insulation level, 20-300VA burden, 200-500VA max output, 50-60Hz, GB1207 IEC60044-2.

LZZBW-10(GY) Outdoor Dry Type Current Transformer 10kV Support Type CT – 20-600A Dual-Ratio 0.2/0.5/10P10 Class Oil-Free Epoxy Resin Casting 12/42/75kV Pollution Class II Unattended Substation GB1208-2006

LZZBW-10(GY) Outdoor Dry Type Current Transformer 10kV Support Type CT - 20-600A Dual-Ratio 0.20.510P10 Class Oil-Free Epoxy Resin Casting 124275kV Pollution Class II Unattended Substation GB1208-2006

LZZBW-10(GY) Outdoor Dry Type Current Transformer 10kV Support Type CT: 20-600A primary current, 0.2/0.5/10P10 accuracy class, dual-ratio configuration 2×5-2×300A, oil-free epoxy resin casting, 12/42/75kV insulation level, pollution class II, 10-15VA burden, maintenance-free, 5A/1A secondary, 50Hz, GB1208-2006, ideal for unattended substations.