JLSZY-6/10W Outdoor Dry Type Combined CT PT Metering Box 6kV/10kV Three-Phase High Voltage – Multi-Tap 7.5-1000A 3×400VA Max Output 0.2S/0.5S Class Pollution IV Epoxy Resin Casting 12/42/75kV Insulation GB17201

JLSZY-6/10W Outdoor Dry Type Combined CT PT Metering Box 6kV/10kV Three-Phase High Voltage - Multi-Tap 7.5-1000A 3×400VA Max Output 0.2S/0.5S Class Pollution IV Epoxy Resin Casting 12/42/75kV Insulation GB17201

JLSZY-6/10W Outdoor Dry Type Combined CT PT Metering Box: 6kV/10kV, outdoor three-phase dry type epoxy resin casting, multi-tap current transformer 7.5-1000A, 6kV-10kV/100V voltage ratio, 0.2S/0.5S accuracy class, pollution class IV, 3×400VA max output, 7.2-12/32-42/60-75kV insulation, 50-60Hz, GB17201.

JLSZW-10/GY Outdoor Dry Type Combined CT PT Metering Box 10kV Three-Phase High Voltage – Epoxy Resin Casting 5-400/5A 300VA Limit Output 0.2S/0.5 Class Enclosed Iron Box 12/42/75kV Insulation GB17201 GB1208 GB1207

JLSZW-10/GY Outdoor Dry Type Combined CT PT Metering Box 10kV Three-Phase High Voltage - Epoxy Resin Casting 5-400/5A 300VA Limit Output 0.2S/0.5 Class Enclosed Iron Box 12/42/75kV Insulation GB17201 GB1208 GB1207

JLSZW-10/GY Outdoor Dry Type Combined CT PT Metering Box: 10kV, outdoor three-phase dry type epoxy resin casting, enclosed iron box structure, 5-400/5A current ratio, 3kV-10kV/100V voltage ratio, 0.2S/0.2/0.5 accuracy class, 300VA limit output, 12/42/75kV insulation, replaces oil-immersed, 50Hz, GB17201 GB1208 GB1207.

JLSZV2-6/10 Outdoor Dry Type Combined CT PT Metering Box 6kV/10kV Three-Phase High Voltage – Multi-Tap 7.5-1000A 2×400VA Max Output 0.2S/0.5S Class Pollution IV Epoxy Resin Casting 12/42/75kV Insulation GB17201

JLSZV2-6/10 Outdoor Dry Type Combined CT PT Metering Box 6kV/10kV Three-Phase High Voltage - Multi-Tap 7.5-1000A 2×400VA Max Output 0.2S/0.5S Class Pollution IV Epoxy Resin Casting 12/42/75kV Insulation GB17201

JLSZV2-6/10 Outdoor Dry Type Combined CT PT Metering Box: 6kV/10kV, outdoor three-phase dry type epoxy resin casting, multi-tap current transformer 7.5-1000A, 6kV-10kV/100V voltage ratio, 0.2S/0.5S accuracy class, pollution class IV, 2×400VA max output, 7.2-12/32-42/60-75kV insulation, 50-60Hz, GB17201.

JLSZ8-10GY Outdoor Combined CT PT Metering Box 10kV Epoxy Resin Casting Energy Measuring Unit – Pillar Type Maintenance-Free V-Connection 5-600/5A Dual Tap 0.2S/0.5 Class Anti-Tamper UV-Resistant GB17201

JLSZ8-10GY Outdoor Combined CT PT Metering Box 10kV Epoxy Resin Casting Energy Measuring Unit - Pillar Type Maintenance-Free V-Connection 5-600/5A Dual Tap 0.2S/0.5 Class Anti-Tamper UV-Resistant GB17201

JLSZ8-10GY Outdoor Combined CT PT Metering Box: 10kV, outdoor epoxy resin casting pillar type, V-connection voltage transformer with dual tap current transformer, 5-600/5A current ratio, 10kV/100V voltage ratio, 0.2S/0.5 accuracy class, maintenance-free, UV-resistant, anti-tamper design, fully enclosed, 50Hz, GB17201.

JLS-6/10/24/35 Outdoor Combined CT PT Metering Box High Voltage Power Metering Unit – Integrated Current Voltage Transformer with Watt-Hour Meter 0.2/0.5/0.2S/0.5S Class Oil-Immersed 5-300/5A 40.5/95/185kV GB17201

JLS-6/10/24/35 Outdoor Combined CT PT Metering Box High Voltage Power Metering Unit - Integrated Current Voltage Transformer with Watt-Hour Meter 0.2/0.5/0.2S/0.5S Class Oil-Immersed 5-300/5A 40.5/95/185kV GB17201

JLS-6/10/24/35 Outdoor Combined CT PT Metering Box: 6kV/10kV/24kV/35kV, outdoor oil-immersed combined current and voltage transformer with integrated watt-hour meter box, 5-300/5A current ratio, 3kV-35kV/100V-110V voltage ratio, 0.2/0.5/0.2S/0.5S accuracy class, 3.6-40.5/24-95/75-185kV insulation, anti-tamper design, 50-60Hz, GB17201.

JDZX12A/JDZ16-3/6/10R Indoor Elbow Type Voltage Transformer 3kV/6kV/10kV with Fuse Cutout – 200A American Elbow Plug Epoxy Resin Casting PT 1000VA Max Output 0.2/0.5/1/3 Class 12/42/75kV Insulation GB1207

JDZX12A/JDZ16-3/6/10R Indoor Elbow Type Voltage Transformer 3kV/6kV/10kV with Fuse Cutout - 200A American Elbow Plug Epoxy Resin Casting PT 1000VA Max Output 0.2/0.5/1/3 Class 12/42/75kV Insulation GB1207

JDZX12A/JDZ16-3/6/10R Indoor Elbow Type Voltage Transformer: 3kV/6kV/10kV, indoor single-phase epoxy resin casting, 200A American elbow plug connection, with fuse cutout, dual/triple secondary winding, 0.2/0.5/1/3 accuracy class, 3.6-12/23-42/40-75kV insulation, 1000VA max output, compact elbow design, 50-60Hz, GB1207 IEC60044-2.

JDZX11-10/JDZX16-10Q Indoor Single-Phase Voltage Transformer 10kV Epoxy Resin Casting PT – 100V/√3+100V/3 Dual/Triple Secondary Grounding Protection 0.2/0.5/1/3/6P Class 600VA Max Output 12/42/75kV Insulation

JDZX11-10/JDZX16-10Q Indoor Single-Phase Voltage Transformer 10kV Epoxy Resin Casting PT - 100V/√3+100V/3 Dual/Triple Secondary Grounding Protection 0.2/0.5/1/3/6P Class 600VA Max Output 12/42/75kV Insulation GB1207

JDZX11-10/JDZX16-10Q Indoor Single-Phase Voltage Transformer: 10kV, indoor single-phase epoxy resin casting, 10kV/√3/100V/√3+100V/3 or 100V/√3+100V/√3+100V/3 ratio, dual/triple secondary winding, grounding protection, 0.2/0.5/1/3/6P accuracy class, 12/42/75kV insulation, 600VA max output, compact design, 50-60Hz, GB1207 IEC60044-2.

JDZX10-3/6/10 Indoor Single-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 100V/√3+100V/3 Dual Secondary Grounding Protection 0.2/0.5/1/3/6P Class 200VA Max Output 12/42/75kV Insulation GB1207

JDZX10-3/6/10 Indoor Single-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT - 100V/√3+100V/3 Dual Secondary Grounding Protection 0.2/0.5/1/3/6P Class 200VA Max Output 12/42/75kV Insulation GB1207

JDZX10-3/6/10 Indoor Single-Phase Voltage Transformer: 3kV/6kV/10kV, indoor single-phase epoxy resin casting, 3kV-10kV/√3/100V/√3+100V/3 ratio, dual secondary winding, grounding protection, 0.2/0.5/1/3/6P accuracy class, 3.6-12/25-42/40-75kV insulation, 200VA max output, compact design, 50-60Hz, GB1207 IEC60044-2.

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – Anti-Magnet Ferroresonance Suppression 100V/√3+100V/√3 Triple Secondary 0.2/0.5/1/3/6P Class 3×400VA GB1207

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT - Anti-Magnet Ferroresonance Suppression 100V/√3+100V/√3 Triple Secondary 0.2/0.5/1/3/6P Class 3×400VA GB1207

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, anti-magnet ferroresonance suppression, 3kV-10kV/√3/100V/√3+100V/√3 ratio, triple secondary winding, 0.2/0.5/1/3/6P accuracy class, 3.6-12/25-42/40-75kV insulation, 3×400VA thermal limit output, 310mm creepage, 50-60Hz, GB1207 IEC60044-2.

JSZV12A-3/6/10 Indoor Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 3000/100 6000/100 10000/100 Dual Secondary 0.2/0.5/1/3 Class 600×√3 VA Ultra-High Output 12/42/75kV GB1207

JSZV12A-3/6/10 Indoor Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT - 3000/100 6000/100 10000/100 Dual Secondary 0.2/0.5/1/3 Class 600×√3 VA Ultra-High Output 12/42/75kV GB1207

JSZV12A-3/6/10 Indoor Three-Phase Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, 3000/100, 6000/100, 10000/100 phase-to-phase ratio, dual secondary winding, 0.2/0.5/1/3 accuracy class, 3.6-12/23-42/40-75kV insulation, 600×√3 VA ultra-high output, compact integrated design, 50-60Hz, GB1207 IEC60044-2.