JDZX11-10/JDZX16-10Q Indoor Single-Phase Voltage Transformer 10kV Epoxy Resin Casting PT – 100V/√3+100V/3 Dual/Triple Secondary Grounding Protection 0.2/0.5/1/3/6P Class 600VA Max Output 12/42/75kV Insulation

JDZX11-10/JDZX16-10Q Indoor Single-Phase Voltage Transformer 10kV Epoxy Resin Casting PT - 100V/√3+100V/3 Dual/Triple Secondary Grounding Protection 0.2/0.5/1/3/6P Class 600VA Max Output 12/42/75kV Insulation GB1207

JDZX11-10/JDZX16-10Q Indoor Single-Phase Voltage Transformer: 10kV, indoor single-phase epoxy resin casting, 10kV/√3/100V/√3+100V/3 or 100V/√3+100V/√3+100V/3 ratio, dual/triple secondary winding, grounding protection, 0.2/0.5/1/3/6P accuracy class, 12/42/75kV insulation, 600VA max output, compact design, 50-60Hz, GB1207 IEC60044-2.

JDZX10-3/6/10 Indoor Single-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 100V/√3+100V/3 Dual Secondary Grounding Protection 0.2/0.5/1/3/6P Class 200VA Max Output 12/42/75kV Insulation GB1207

JDZX10-3/6/10 Indoor Single-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT - 100V/√3+100V/3 Dual Secondary Grounding Protection 0.2/0.5/1/3/6P Class 200VA Max Output 12/42/75kV Insulation GB1207

JDZX10-3/6/10 Indoor Single-Phase Voltage Transformer: 3kV/6kV/10kV, indoor single-phase epoxy resin casting, 3kV-10kV/√3/100V/√3+100V/3 ratio, dual secondary winding, grounding protection, 0.2/0.5/1/3/6P accuracy class, 3.6-12/25-42/40-75kV insulation, 200VA max output, compact design, 50-60Hz, GB1207 IEC60044-2.

JLSZY-35 Outdoor Combined Transformer 35kV CT PT Metering Unit – Current Voltage Transformer 5-600/5A 35kV/100V Epoxy Resin Casting 0.2S/0.5 Class 350VA Energy Metering Box Y/Y Connection GB1208 GB1207

JLSZY-35 Outdoor Combined Transformer 35kV CT PT Metering Unit - Current Voltage Transformer 5-600/5A 35kV/100V Epoxy Resin Casting 0.2S/0.5 Class 350VA Energy Metering Box Y/Y Connection GB1208 GB1207

JLSZY-35 Outdoor Combined Transformer 35kV CT PT Metering Unit: 35kV high voltage, outdoor epoxy resin casting, combined current and voltage transformer, 5-600/5A CT ratio, 35kV/100V PT ratio, 0.2S/0.5 accuracy class, 350VA thermal output, Y/Y connection, energy metering box, anti-tamper, pillar-type structure, 50Hz, GB1208 GB1207 GB17201.

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – Anti-Magnet Ferroresonance Suppression 100V/√3+100V/√3 Triple Secondary 0.2/0.5/1/3/6P Class 3×400VA GB1207

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT - Anti-Magnet Ferroresonance Suppression 100V/√3+100V/√3 Triple Secondary 0.2/0.5/1/3/6P Class 3×400VA GB1207

JSZJK-3/6/10 Indoor Three-Phase Anti-Resonance Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, anti-magnet ferroresonance suppression, 3kV-10kV/√3/100V/√3+100V/√3 ratio, triple secondary winding, 0.2/0.5/1/3/6P accuracy class, 3.6-12/25-42/40-75kV insulation, 3×400VA thermal limit output, 310mm creepage, 50-60Hz, GB1207 IEC60044-2.

JSZV12A-3/6/10 Indoor Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 3000/100 6000/100 10000/100 Dual Secondary 0.2/0.5/1/3 Class 600×√3 VA Ultra-High Output 12/42/75kV GB1207

JSZV12A-3/6/10 Indoor Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT - 3000/100 6000/100 10000/100 Dual Secondary 0.2/0.5/1/3 Class 600×√3 VA Ultra-High Output 12/42/75kV GB1207

JSZV12A-3/6/10 Indoor Three-Phase Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, 3000/100, 6000/100, 10000/100 phase-to-phase ratio, dual secondary winding, 0.2/0.5/1/3 accuracy class, 3.6-12/23-42/40-75kV insulation, 600×√3 VA ultra-high output, compact integrated design, 50-60Hz, GB1207 IEC60044-2.

JSZW-3/6/10 Indoor Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 100V/√3+100V/3 Triple Secondary Grounding Protection 0.2/0.5/1/3/6P Class 600VA High Output 12/42/75kV Insulation GB1207

JSZW-3 6 10 Indoor Three-Phase Voltage Transformer 3kV 6kV 10kV Epoxy Resin Casting PT

JSZW-3/6/10 Indoor Three-Phase Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, 3kV-10kV/√3/100V/√3+100V/3 ratio, triple secondary winding, grounding protection, 0.2/0.5/1/3/6P accuracy class, 3.6-12/23-42/40-75kV insulation, 600VA max output, compact integrated design, 50-60Hz, GB1207 IEC60044-2.

JSZW-35 Outdoor Three-Phase Voltage Transformer 35kV Epoxy Resin Casting PT – German CY1680 Fully Enclosed 100V/√3+100V/√3 Dual Secondary 0.2/0.5/3P Class 600VA High Output 40.5/95/185kV Insulation GB1207

JSZW-35 Outdoor Three-Phase Voltage Transformer 35kV Epoxy Resin Casting PT - German CY1680 Fully Enclosed 100V/√3+100V/√3 Dual Secondary 0.2/0.5/3P Class 600VA High Output 40.5/95/185kV Insulation GB1207

JSZW-35 Outdoor Three-Phase Voltage Transformer 35kV Epoxy Resin Casting PT: German CY1680 epoxy resin, fully enclosed pillar-type structure, 35kV/√3/100V/√3+100V/√3 dual secondary ratio, 0.2/0.5/3P accuracy class, 40.5/95/185kV insulation level, 600VA high output, pollution-resistant, UV-resistant, warm zone suitable, compact three-phase integrated, 50Hz, GB1207-2006.

JSZWK-3/6/10 Outdoor Anti-Resonance Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 100V/√3+100V Triple Secondary Ferroresonance Suppression 0.2/0.5/6P Class 1500VA High Output 12/42/75kV GB1207

JSZWK-3/6/10 Outdoor Anti-Resonance Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT - 100V/√3+100V Triple Secondary Ferroresonance Suppression 0.2/0.5/6P Class 1500VA High Output 12/42/75kV GB1207

JSZWK-3/6/10 Outdoor Anti-Resonance Three-Phase Voltage Transformer: 3kV/6kV/10kV, outdoor three-phase epoxy resin casting, ferroresonance suppression, 3kV-10kV/√3/100V/√3+100V ratio, triple secondary winding, 0.2/0.5/6P accuracy class, 3.6-12/25-42/40-75kV insulation, 1500VA max output, weather-resistant, 50-60Hz, GB1207 IEC60044-2.

JDZX9-35 Indoor Voltage Transformer 35kV Single-Phase Epoxy Resin Casting PT – Phase-to-Ground 100V/√3+100V/3 Triple Secondary 0.2/0.5/1/3/6P Class Open Delta Grounding Protection 1000VA High Output 40.5/95/200kV GB1207

JDZX9-35 Indoor Voltage Transformer 35kV Single-Phase Epoxy Resin Casting PT - Phase-to-Ground 100V/√3+100V/3 Triple Secondary 0.2/0.5/1/3/6P Class Open Delta Grounding Protection 1000VA High Output 40.5/95/200kV GB1207

JDZX9-35 Indoor Voltage Transformer 35kV Single-Phase Epoxy Resin Casting PT: Phase-to-ground measurement, 35kV/√3/100V/√3+100V/3 ratio, triple secondary winding, open delta grounding protection, 0.2/0.5/1/3/6P accuracy class, pillar-type fully enclosed, 40.5/95/200kV insulation, 1000VA max output, 1-second short circuit withstand, 50-60Hz, GB1207 IEC60044-2.

JDZW-35 Outdoor Voltage Transformer 35kV Single-Phase Epoxy Resin Casting PT – Swiss Ciba CW5837 Fully Enclosed 0.2/0.5 Class Dual Secondary 1000VA High Output 40.5/95/200kV Insulation

JDZW-35 Outdoor Voltage Transformer 35kV Single-Phase Epoxy Resin Casting PT - Swiss Ciba CW5837 Fully Enclosed 0.2 0.5 Class Dual Secondary 1000VA High Output 40.5 95 200kV Insulation

JDZW-35 Outdoor Voltage Transformer 35kV Single-Phase Epoxy Resin Casting PT: Swiss Ciba CW5837 epoxy resin, fully enclosed hermetically sealed, 35kV/0.1kV ratio, 0.2/0.5 accuracy class, dual secondary option, pillar-type structure, 40.5/95/200kV insulation level, 1000VA high output, arc-resistant, UV-resistant, anti-aging, 50-60Hz, GB1207 IEC60044-2.