Specializing in the production of insulation products

JDZX11-10/JDZX16-10Q Indoor Single-Phase Voltage Transformer 10kV Epoxy Resin Casting PT – 100V/√3+100V/3 Dual/Triple Secondary Grounding Protection 0.2/0.5/1/3/6P Class 600VA Max Output 12/42/75kV Insulation

Description:

JDZX11-10/JDZX16-10Q Indoor Single-Phase Voltage Transformer: 10kV, indoor single-phase epoxy resin casting, 10kV/√3/100V/√3+100V/3 or 100V/√3+100V/√3+100V/3 ratio, dual/triple secondary winding, grounding protection, 0.2/0.5/1/3/6P accuracy class, 12/42/75kV insulation, 600VA max output, compact design, 50-60Hz, GB1207 IEC60044-2.

Applications:

Advanced JDZX11-10/JDZX16-10Q indoor single-phase voltage transformer featuring epoxy resin casting, conforming to GB1207 and IEC60044-2 standards, 10kV rated voltage, insulation level 12/42/75kV, rated frequency 50Hz or 60Hz, designed for indoor single-phase power systems, JDZX11-10 offers dual secondary configuration with 100V/√3 measuring winding plus 100V/3 residual voltage winding, JDZX16-10Q provides triple secondary with dual 100V/√3 measuring windings plus 100V/3 residual voltage winding for comprehensive voltage measurement and grounding protection.

Superior high output capacity with 600VA maximum output for JDZX11-10 dual secondary configuration and 300/300VA for JDZX16-10Q triple secondary supports extensive indoor multiple load connections, accuracy classes 0.2/0.5/1/3/6P available for various metering and protection requirements, compact single-phase design suitable for indoor substations, indoor switchgear, and metal-clad equipment requiring reliable single-phase voltage measurement with grounding protection, three units required for complete three-phase system monitoring.

Specifications

JDZX11-10/JDZX16-10Q Indoor Single-Phase Voltage Transformer 10kV Epoxy Resin Casting PT - 100V/√3+100V/3 Dual/Triple Secondary Grounding Protection 0.2/0.5/1/3/6P Class 600VA Max Output 12/42/75kV Insulation GB1207

Features

JDZX11-10/JDZX16-10Q Indoor Single-Phase Voltage Transformer Specifications Parameter Unit
Brand Bepto Insulation Systems
Model Number JDZX11-10, JDZX16-10Q
Category Switchgear & HV PT (High Voltage Potential Transformer)
Product Type 10kV Indoor Single-Phase Epoxy Resin Casting Voltage Transformer with Dual/Triple Secondary Winding, Grounding Protection, 0.2/0.5/1/3/6P Accuracy Class, 12/42/75kV Insulation, 600VA Maximum Output for Indoor Single-Phase Voltage & Energy Measurement and Grounding Protection
Core Technology Indoor Single-Phase Epoxy Resin Casting Design + 10kV Medium Voltage + GB1207 and IEC60044-2 Standards Compliant + Rated Insulation Level 12/42/75kV + Rated Frequency 50Hz or 60Hz + Phase-to-Ground Voltage Ratio (10kV/√3/100V/√3+100V/3 or 100V/√3+100V/√3+100V/3) + Dual/Triple Secondary Winding Configuration + Accuracy Classes (0.2, 0.5, 1, 3, 6P) + Rated Secondary Load 15-500VA + Maximum Output 300-600VA + Compact Single-Phase Design + Proven Epoxy Resin Technology
Power (Voltage) 10kV
Installation Type Indoor
Phase Single Phase (Three Units Required for Three-Phase System)
Rated Voltage (JDZX11-10) 10kV/√3 (5.77kV) per phase
Rated Voltage (JDZX16-10Q) 10kV/√3 (5.77kV) per phase
Voltage Ratio (JDZX11-10 Dual) 10000/√3/100/√3 + 100/3 V
Voltage Ratio (JDZX16-10Q Triple) 10000/√3/100/√3 + 100/√3 + 100/3 V
Secondary Measuring Winding 1 100V/√3 (57.7V) V
Secondary Measuring Winding 2 (JDZX16-10Q) 100V/√3 (57.7V) V
Residual Voltage Winding 100V/3 (33.3V) V
Rated Frequency 50Hz or 60Hz Hz
Accuracy Classes 0.2, 0.5, 1, 3, 6P
Insulation Level 12/42/75 kV
Max Output (JDZX11-10 Dual) 600 VA
Max Output (JDZX16-10Q Triple) 300/300 VA
Rated Secondary Load (0.2 Class) 30 VA
Rated Secondary Load (0.5 Class) 90 VA
Rated Secondary Load (1 Class) 200 VA
Rated Secondary Load (3 Class) 500 VA
Rated Secondary Load (6P Class) 100 VA
Rated Secondary Load (0.2/0.2 Triple) 15/15 VA
Rated Secondary Load (0.2/0.5 Triple) 15/20 VA
Rated Secondary Load (0.5/0.5 Triple) 50/50 VA
Insulation Type Indoor Epoxy Resin Casting
Structure Type Indoor Single-Phase Epoxy Resin Casting
Voltage Level Medium Voltage (10kV)
Standards Compliance GB1207 and IEC60044-2
FOB Port Ningbo/Shanghai
Terms of Payment Western Union, T/T, Paypal
10kV Medium Voltage Yes (10kV Rated Voltage)
Indoor Single-Phase Yes (Indoor Single-Phase Configuration)
Indoor Epoxy Resin Casting Yes (Indoor Epoxy Resin Casting Insulation)
600VA Max Output Yes (600VA Maximum Output for Dual Secondary)
300/300VA Triple Output Yes (300/300VA Maximum Output for Triple Secondary)
100V/√3+100V/3 Ratio Yes (Phase-to-Ground Measurement + Residual Voltage)
Dual Secondary Winding Yes (JDZX11-10 Dual Secondary Configuration)
Triple Secondary Winding Yes (JDZX16-10Q Triple Secondary Configuration)
Grounding Protection Yes (100V/3 Residual Voltage Winding)
50Hz or 60Hz Yes (Rated Frequency 50Hz or 60Hz)
GB1207 Compliant Yes (In Accordance with GB1207 Standard)
IEC60044-2 Compliant Yes (In Accordance with IEC60044-2 Standard)
12/42/75kV Insulation Yes (Rated Insulation Level)
0.2 Accuracy Class Yes (0.2 Metering Accuracy Class Available)
0.5 Accuracy Class Yes (0.5 Metering Accuracy Class Available)
1 Accuracy Class Yes (1 Monitoring Accuracy Class Available)
3 Accuracy Class Yes (3 Monitoring Accuracy Class Available)
6P Protection Class Yes (6P Protection Accuracy Class Available)
Compact Single-Phase Design Yes (Compact Single-Phase Unit)
Flexible Secondary Configuration Yes (Dual or Triple Secondary Options)
Model Secondary Configuration Voltage Ratio Max Output Accuracy Classes Application
JDZX11-10 Dual Secondary 10kV/√3/100V/√3 + 100V/3 600VA 0.2, 0.5, 1, 3, 6P 10kV indoor single-phase measurement + grounding protection with high output capacity
JDZX16-10Q Triple Secondary 10kV/√3/100V/√3 + 100V/√3 + 100V/3 300/300VA 0.2/0.2, 0.2/0.5, 0.5/0.5 10kV indoor dual metering + grounding protection with independent measuring circuits
JDZX11-10 with dual secondary windings (10 kV, indoor, single-phase)
Accuracy Class Rated Secondary Load (VA) Max Output (VA) Application
0.2 30 600 High-precision indoor single-phase revenue metering for 10kV systems
0.5 90 600 Standard indoor single-phase metering and monitoring for 10kV systems
1 200 600 General indoor single-phase voltage monitoring for 10kV systems
3 500 600 Indoor single-phase monitoring and instrumentation for 10kV systems
6P 100 600 Indoor single-phase relay protection and grounding protection for 10kV systems
JDZX16-10Q with three secondary windings (10 kV, indoor, single-phase)
Accuracy Class Combination Rated Secondary Load (VA) Max Output (VA) Application
0.2/0.2 15/15 300/300 Dual high-precision indoor single-phase metering for 10kV systems
0.2/0.5 15/20 300/300 High-precision indoor metering + standard monitoring for 10kV systems
0.5/0.5 50/50 300/300 Dual standard indoor single-phase metering for 10kV systems
600VA Maximum Output Capacity Feature Description Benefit
600VA Maximum Output (JDZX11-10) 600VA maximum output capacity for dual secondary configuration Highest output capacity for indoor single-phase 10kV transformers
High Capacity Metering Adequate capacity for extensive indoor multiple load connections Supports numerous metering devices, relays, and monitoring equipment
Indoor Single-Phase Application Maximum output capacity for indoor single-phase 10kV systems Adequate capacity for comprehensive indoor distribution loads
Multiple Load Support Can drive multiple indoor metering devices and relays Eliminates need for additional transformers
Indoor SCADA Systems Sufficient capacity for indoor single-phase data acquisition Enables advanced indoor monitoring and control
Future Expansion Excess capacity for indoor system upgrades Flexibility for indoor single-phase system expansion
300/300VA Triple Secondary Output Feature Description Benefit
300/300VA Dual Measuring Output 300VA output for each of two independent measuring windings High capacity for dual independent metering circuits
Independent Metering Circuits Two separate 100V/√3 measuring windings Enables independent billing and monitoring metering
Dual Metering Application Supports dual metering for separate customers or applications Ideal for split metering or redundant metering systems
Grounding Protection Additional 100V/3 residual voltage winding Comprehensive ground fault detection with dual metering
Flexible Secondary Configuration Feature Description Benefit
Dual Secondary Option (JDZX11-10) Single measuring winding + residual voltage winding Standard metering + grounding protection with high 600VA output
Triple Secondary Option (JDZX16-10Q) Dual measuring windings + residual voltage winding Dual independent metering + grounding protection with 300/300VA output
Application Flexibility Choose dual or triple secondary based on application requirements Optimized configuration for specific metering needs
High Output Dual (JDZX11-10) 600VA output for high-load single metering applications Maximum capacity for extensive load connections
Dual Metering Triple (JDZX16-10Q) 300/300VA output for dual independent metering applications Adequate capacity for split or redundant metering
Indoor Single-Phase 10kV Application Scenario Recommended Model Key Advantage Typical Installation
Indoor Substations (High Load) JDZX11-10 600VA high output + grounding protection Indoor 10kV distribution substations (three units)
Indoor Switchgear (High Load) JDZX11-10 600VA output for extensive load connections Indoor 10kV metal-clad switchgear (three units)
Indoor Dual Metering Applications JDZX16-10Q Triple secondary for dual independent metering + grounding protection Indoor 10kV dual billing or redundant metering (three units)
Indoor Energy Measurement (High Precision) JDZX11-10 (0.2 class) High-precision 0.2 class + 600VA output Indoor 10kV revenue metering systems (three units)
Indoor Split Metering JDZX16-10Q Dual 100V/√3 measuring windings for separate metering Indoor 10kV split customer metering (three units)
Indoor Relay Protection (High Load) JDZX11-10 (6P class) 100V/3 residual voltage + 600VA output for relays Indoor 10kV protection relay systems (three units)
Indoor Grounding Protection JDZX11-10 or JDZX16-10Q 100V/3 residual voltage winding for ground fault detection Indoor 10kV ground fault protection systems (three units)
Feature JDZX11-10 (10kV Dual High Output) JDZX16-10Q (10kV Triple Dual Metering) JDZX10-10 (10kV Standard Dual)
Secondary Configuration Dual secondary Triple secondary Dual secondary
Voltage Ratio 10kV/√3/100V/√3 + 100V/3 10kV/√3/100V/√3 + 100V/√3 + 100V/3 10kV/√3/100V/√3 + 100V/3
Maximum Output 600VA 300/300VA 200VA
Accuracy Classes 0.2, 0.5, 1, 3, 6P 0.2/0.2, 0.2/0.5, 0.5/0.5 0.2, 0.5, 1, 3, 6P
Key Advantage Highest 600VA output for high-load applications Dual independent metering with 300/300VA output Standard 200VA output for general applications
Typical Application High-load indoor substations, extensive metering devices Dual billing, split metering, redundant metering Standard indoor substations, general metering
Feature JDZX11-10/JDZX16-10Q (10kV Indoor) JDZX9-35 (35kV Indoor) JDZW-35 (35kV Outdoor)
Voltage Level 10kV (medium voltage) 35kV (high voltage) 35kV (high voltage)
Installation Type Indoor Indoor Outdoor
Maximum Output 600VA (dual), 300/300VA (triple) 1000VA 1000VA
Secondary Configuration Dual or triple Dual or triple Dual or triple
Key Advantage 10kV + 600VA high output + dual/triple options 35kV + 1000VA ultra-high output + indoor 35kV + 1000VA ultra-high output + outdoor hermetically sealed
Typical Application Indoor 10kV substations, switchgear Indoor 35kV substations, switchgear Outdoor 35kV substations, overhead lines

Let The World Know About Bepto

Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.

Application

ANYTHING YOU COULDN’T FIND?
Talk With Our Sales

Bepto focuses on the global market and provides our clients with products suitable for the local market:

SEND US AN EMAIL
Contact Us

Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.

Form Contact 2
Bepto Logo red
Get More Benefits Since Submit The Info Form
Form Contact