Specializing in the production of insulation products

JSZW-3/6/10 Indoor Three-Phase Voltage Transformer 3kV/6kV/10kV Epoxy Resin Casting PT – 100V/√3+100V/3 Triple Secondary Grounding Protection 0.2/0.5/1/3/6P Class 600VA High Output 12/42/75kV Insulation GB1207

Description:

JSZW-3/6/10 Indoor Three-Phase Voltage Transformer: 3kV/6kV/10kV, indoor three-phase epoxy resin casting, 3kV-10kV/√3/100V/√3+100V/3 ratio, triple secondary winding, grounding protection, 0.2/0.5/1/3/6P accuracy class, 3.6-12/23-42/40-75kV insulation, 600VA max output, compact integrated design, 50-60Hz, GB1207 IEC60044-2.

Applications:

Advanced JSZW indoor three-phase voltage transformer featuring epoxy resin casting, conforming to GB1207 and IEC60044-2 standards, three voltage levels (3kV, 6kV, 10kV), rated insulation levels 3.6/23/40kV, 7.2/32/60kV, and 12/42/75kV, rated frequency 50Hz or 60Hz, designed for indoor three-phase power systems, 100V/√3 secondary measuring winding plus 100V/3 residual voltage winding for comprehensive voltage measurement and grounding protection applications.

Superior compact three-phase integrated design reduces indoor installation space versus three separate single-phase units, exceptional 600VA maximum output capacity supports multiple indoor metering devices and relays, triple secondary winding configurations available (JSZW and JSZW3 series) for dual metering plus grounding protection, Type A and Type B variants offer flexible installation options, suitable for indoor substations, indoor switchgear, and metal-clad equipment requiring reliable three-phase voltage measurement with grounding protection.

Specifications

JSZW-3 6 10 Indoor Three-Phase Voltage Transformer 3kV 6kV 10kV Epoxy Resin Casting PT

Features

JSZW-3/6/10 Indoor Three-Phase Voltage Transformer Specifications Parameter Unit
Brand Bepto Insulation Systems
Model Number JSZW-3/6/10 Series (JSZW-3A/B, JSZW-6A/B, JSZW-10A/B, JSZW3-3A/B, JSZW3-6A/B, JSZW3-10A/B)
Category Switchgear & HV PT (High Voltage Potential Transformer)
Product Type 3kV/6kV/10kV Indoor Three-Phase Epoxy Resin Casting Voltage Transformer with Triple Secondary Winding, Grounding Protection, 0.2/0.5/1/3/6P Accuracy Class, 3.6-12/23-42/40-75kV Insulation, 600VA High Output Capacity for Indoor Three-Phase Voltage & Energy Measurement and Grounding Protection
Core Technology Indoor Three-Phase Epoxy Resin Casting Design + Multi-Voltage Flexibility (3kV/6kV/10kV) + Integrated Three-Phase Configuration + GB1207 and IEC60044-2 Standards Compliant + Rated Insulation Levels (3.6/23/40kV, 7.2/32/60kV, 12/42/75kV) + Rated Frequency 50Hz or 60Hz + Phase-to-Ground Voltage Ratio (3kV-10kV/√3/100V/√3+100V/3) + Triple Secondary Winding Configuration + Accuracy Classes (0.2, 0.5, 1, 3, 6P) + Rated Secondary Load 30-600VA + Maximum Output 300-600VA + Compact Three-Phase Integrated Design + Type A and Type B Variants + Proven Epoxy Resin Technology
Power (Voltage) 3kV / 6kV / 10kV
Installation Type Indoor
Phase Three Phase (Integrated)
Rated Voltage (JSZW-3) 3kV/√3 (1.73kV) per phase
Rated Voltage (JSZW-6) 6kV/√3 (3.46kV) per phase
Rated Voltage (JSZW-10) 10kV/√3 (5.77kV) per phase
Voltage Ratio (JSZW-3) 3000/√3/100/√3 + 100/3 V
Voltage Ratio (JSZW-6 Dual) 6000/√3/100/√3 + 100/3 V
Voltage Ratio (JSZW-10 Dual) 10000/√3/100/√3 + 100/3 V
Voltage Ratio (JSZW-6 Triple) 6000/√3/100/√3 + 100/√3 + 100/3 V
Voltage Ratio (JSZW-10 Triple) 10000/√3/100/√3 + 100/√3 + 100/3 V
Secondary Measuring Winding 100V/√3 (57.7V) V
Residual Voltage Winding 100V/3 (33.3V) V
Rated Frequency 50Hz or 60Hz Hz
Accuracy Classes 0.2, 0.5, 1, 3, 6P
Insulation Level (JSZW-3) 3.6/23/40 kV
Insulation Level (JSZW-6) 7.2/32/60 kV
Insulation Level (JSZW-10) 12/42/75 kV
Max Output (JSZW-3/6/10 Dual) 600 VA
Max Output (JSZW-6/10 Triple) 450/450 VA
Max Output (JSZW3-10B Triple) 300/300 VA
Rated Secondary Load (0.2 Class) 30-60 VA
Rated Secondary Load (0.5 Class) 90-150 VA
Rated Secondary Load (1 Class) 150-240 VA
Rated Secondary Load (3 Class) 300-600 VA
Rated Secondary Load (0.2/0.2 Dual) 30/30-45/60 VA
Rated Secondary Load (0.2/0.5 Dual) 60/60 VA
Rated Secondary Load (0.5/0.5 Dual) 90/90 VA
Rated Secondary Load (6P Class) 75 VA
Insulation Type Indoor Epoxy Resin Casting
Structure Type Indoor Three-Phase Integrated Epoxy Resin Casting
Voltage Level Low-Medium Voltage (3kV/6kV/10kV)
Type Variants Type A and Type B
Standards Compliance GB1207 and IEC60044-2
FOB Port Ningbo/Shanghai
Terms of Payment Western Union, T/T, Paypal
Multi-Voltage 3kV/6kV/10kV Yes (Three Voltage Levels Available)
Indoor Three-Phase Yes (Indoor Three-Phase Integrated Configuration)
Indoor Epoxy Resin Casting Yes (Indoor Epoxy Resin Casting Insulation)
Three-Phase Integrated Yes (Three-Phase Integrated Design)
600VA High Output Yes (600VA Maximum Output for Dual Secondary)
100V/√3+100V/3 Ratio Yes (Phase-to-Ground Measurement + Residual Voltage)
Triple Secondary Winding Yes (Triple Secondary Available)
Grounding Protection Yes (100V/3 Residual Voltage Winding)
Type A Variant Yes (Type A Configuration Available)
Type B Variant Yes (Type B Configuration Available)
50Hz or 60Hz Yes (Rated Frequency 50Hz or 60Hz)
GB1207 Compliant Yes (In Accordance with GB1207 Standard)
IEC60044-2 Compliant Yes (In Accordance with IEC60044-2 Standard)
3.6-12/23-42/40-75kV Insulation Yes (Rated Insulation Levels)
0.2 Accuracy Class Yes (0.2 Metering Accuracy Class Available)
0.5 Accuracy Class Yes (0.5 Metering Accuracy Class Available)
1 Accuracy Class Yes (1 Monitoring Accuracy Class Available)
3 Accuracy Class Yes (3 Monitoring Accuracy Class Available)
6P Protection Class Yes (6P Protection Accuracy Class Available)
Compact Three-Phase Design Yes (Integrated Three-Phase Reduces Space)
Cost-Effective Yes (Single Three-Phase Unit vs. Three Single-Phase Units)
JSZW Series (Indoor three-phase with dual secondary windings)
Model Type Rated Voltage Voltage Ratio Insulation Level Max Output Application
JSZW-3A/B 3kV/√3 (1.73kV) 3kV/√3/100V/√3 + 100V/3 3.6/23/40kV 600VA 3kV indoor three-phase measurement + grounding protection
JSZW-6A/B (Dual) 6kV/√3 (3.46kV) 6kV/√3/100V/√3 + 100V/3 7.2/32/60kV 600VA 6kV indoor three-phase measurement + grounding protection
JSZW-10A/B (Dual) 10kV/√3 (5.77kV) 10kV/√3/100V/√3 + 100V/3 12/42/75kV 600VA 10kV indoor three-phase measurement + grounding protection
JSZW-6A/B (Triple) 6kV/√3 (3.46kV) 6kV/√3/100V/√3 + 100V/√3 + 100V/3 7.2/32/60kV 450/450VA 6kV indoor dual metering + grounding protection
JSZW-10A/B (Triple) 10kV/√3 (5.77kV) 10kV/√3/100V/√3 + 100V/√3 + 100V/3 12/42/75kV 450/450VA 10kV indoor dual metering + grounding protection
JSZW3 Series (Indoor three-phase with dual secondary windings)
Model Type Rated Voltage Voltage Ratio Insulation Level Max Output Application
JSZW3-3A/B 3kV/√3 (1.73kV) 3kV/√3/100V/√3 + 100V/3 3.6/23/40kV 600VA 3kV indoor three-phase measurement + grounding protection
JSZW3-6A/B 6kV/√3 (3.46kV) 6kV/√3/100V/√3 + 100V/3 7.2/32/60kV 600VA 6kV indoor three-phase measurement + grounding protection
JSZW3-10A 10kV/√3 (5.77kV) 10kV/√3/100V/√3 + 100V/3 12/42/75kV 600VA 10kV indoor three-phase measurement + grounding protection
JSZW3-10B (Triple) 10kV/√3 (5.77kV) 10kV/√3/100V/√3 + 100V/√3 + 100V/3 12/42/75kV 300/300VA 10kV indoor dual metering + grounding protection
Type Variant Description Application
Type A Standard configuration for general indoor applications Standard indoor substations and switchgear
Type B Alternative configuration for specific installation requirements Special indoor installations with specific mounting needs
Flexible Options Type A and Type B provide installation flexibility Accommodates various indoor switchgear configurations
Indoor Three-Phase Integrated Structure Feature Description Benefit
Three-Phase Integrated Design Three phases integrated into single indoor unit Compact installation vs. three separate single-phase units
Space-Efficient Significantly reduced indoor installation footprint Ideal for space-constrained indoor substations
Cost-Effective Single three-phase unit vs. three single-phase units Reduced equipment and installation costs
Simplified Installation Single unit installation vs. three separate units Faster indoor installation and commissioning
Unified Insulation Consistent insulation across all three phases Balanced performance and reliability
Indoor Epoxy Resin Casting Indoor-grade epoxy resin for all three phases Reliable operation in indoor environments
Compact Indoor Footprint Minimal indoor mounting space required Suitable for compact indoor substations and switchgear
Integrated Grounding Protection 100V/3 residual voltage winding for three-phase grounding protection Comprehensive ground fault detection
Model Voltage Level Installation Winding Configuration Accuracy Class / Combination Rated Secondary Load (VA) Max Output (VA) Application
JSZW-3A/B 3kV Indoor Dual secondary 0.2 45 600 High-precision indoor three-phase revenue metering
JSZW-3A/B 3kV Indoor Dual secondary 0.5 90 600 Standard indoor three-phase metering and monitoring
JSZW-3A/B 3kV Indoor Dual secondary 1 150 600 General indoor three-phase voltage monitoring
JSZW-3A/B 3kV Indoor Dual secondary 3 300 600 Indoor three-phase monitoring and instrumentation
JSZW-6A/B 6kV Indoor Dual secondary 0.2 45 600 High-precision indoor three-phase revenue metering
JSZW-6A/B 6kV Indoor Dual secondary 0.5 90 600 Standard indoor three-phase metering and monitoring
JSZW-6A/B 6kV Indoor Dual secondary 1 150 600 General indoor three-phase voltage monitoring
JSZW-6A/B 6kV Indoor Dual secondary 3 300 600 Indoor three-phase monitoring and instrumentation
JSZW-10A/B 10kV Indoor Dual secondary 0.2 60 600 High-precision indoor three-phase revenue metering
JSZW-10A/B 10kV Indoor Dual secondary 0.5 90 600 Standard indoor three-phase metering and monitoring
JSZW-10A/B 10kV Indoor Dual secondary 1 150 600 General indoor three-phase voltage monitoring
JSZW-10A/B 10kV Indoor Dual secondary 3 300 600 Indoor three-phase monitoring and instrumentation
JSZW-10A/B 10kV Indoor Dual secondary 6P 75 600 Relay protection and grounding protection
JSZW-6A/B 6kV Indoor Triple secondary 0.2 / 0.2 30 / 30 450 / 450 Dual high-precision three-phase metering
JSZW-6A/B 6kV Indoor Triple secondary 0.2 / 0.5 60 / 60 450 / 450 High-precision metering + standard monitoring
JSZW-10A/B 10kV Indoor Triple secondary 0.2 / 0.2 30 / 30 450 / 450 Dual high-precision three-phase metering
JSZW-10A/B 10kV Indoor Triple secondary 0.2 / 0.5 60 / 60 450 / 450 High-precision metering + standard monitoring
JSZW3-10A 10kV Indoor Dual secondary 0.2 60 600 High-precision indoor three-phase revenue metering
JSZW3-10A 10kV Indoor Dual secondary 0.5 150 600 Standard indoor three-phase metering and monitoring
JSZW3-10A 10kV Indoor Dual secondary 1 240 600 General indoor three-phase voltage monitoring
JSZW3-10A 10kV Indoor Dual secondary 3 600 600 Indoor three-phase monitoring and instrumentation
JSZW3-10B 10kV Indoor Triple secondary 0.2 / 0.2 45 / 45, 45 / 60 300 / 300 Dual high-precision three-phase metering
JSZW3-10B 10kV Indoor Triple secondary 0.5 / 0.5 90 / 90 300 / 300 Dual standard three-phase metering
600VA High Output Capacity Feature Description Benefit
600VA Maximum Output (Dual Secondary) 600VA maximum output capacity for dual secondary configuration Supports extensive indoor three-phase multiple load connections
450/450VA Output (Triple Secondary) 450/450VA output capacity for triple secondary configuration High capacity for dual indoor three-phase metering applications
300/300VA Output (JSZW3-10B) 300/300VA output capacity for JSZW3-10B triple secondary Adequate capacity for dual indoor metering + grounding protection
Indoor Three-Phase Application High output capacity for indoor three-phase systems Adequate capacity for indoor distribution loads
Multiple Load Support Can drive numerous indoor metering devices and relays Eliminates need for multiple indoor three-phase transformers
Indoor SCADA Systems Sufficient capacity for indoor data acquisition Enables advanced indoor monitoring and control
Indoor Three-Phase Application Scenario Recommended Model Key Advantage Typical Installation
Indoor Substations JSZW-3/6/10A/B Compact three-phase integrated design + 600VA output Indoor distribution substations
Indoor Switchgear JSZW-3/6/10A/B Three-phase integrated for indoor metal-clad switchgear Indoor GIS, AIS, metal-clad switchgear
Indoor Dual Metering + Grounding Protection JSZW-6/10A/B (Triple) Triple secondary for dual metering + grounding protection Indoor billing + monitoring + protection applications
Indoor Energy Measurement JSZW-3/6/10A/B High-precision three-phase energy metering Indoor revenue metering systems
Indoor Relay Protection JSZW-10A/B 100V/3 residual voltage for ground fault relays Indoor protection relay systems
Space-Constrained Indoor Installations JSZW-3/6/10A/B Compact three-phase integrated vs. three single-phase units Indoor substations with limited space
Type A/B Specific Requirements JSZW-3/6/10A or B Type A/B variants for specific installation needs Various indoor switchgear configurations
Feature JSZW Series JSZW3 Series
Rated Secondary Load (0.5 Class) 90VA (3kV/6kV/10kV) 90-150VA (3kV/6kV/10kV)
Rated Secondary Load (3 Class) 300VA (3kV/6kV/10kV) 300-600VA (3kV/6kV/10kV)
Max Output (10kV Triple) 450/450VA 300/300VA
JSZW3-10A Advantage Higher load capacity (0.5: 150VA, 3: 600VA)
JSZW3-10B Configuration More accuracy class combinations (0.2/0.2, 0.5/0.5)
Typical Application Standard indoor three-phase applications Higher load capacity and more flexible configurations
Feature JSZW-3/6/10 (Indoor Three-Phase) JSZWK-3/6/10 (Outdoor Anti-Resonance Three-Phase) JSZW-35 (35kV Outdoor Three-Phase)
Voltage Level 3-10kV (medium voltage) 3-10kV (medium voltage) 35kV (high voltage)
Installation Type Indoor Outdoor Outdoor
Anti-Resonance No Yes (ferroresonance suppression) No
Maximum Output 600VA (dual), 450/450VA (triple) 1000-1500VA 600VA
Epoxy Resin Type Standard indoor-grade Standard outdoor-grade German CY1680 (outdoor premium)
Key Advantage Indoor three-phase + compact + 600VA output Anti-resonance + ferroresonance suppression + 1500VA output 35kV high voltage + German CY1680 premium
Typical Application Indoor substations, indoor switchgear Outdoor ungrounded systems, resonant grounded systems 35kV outdoor substations, overhead lines

Let The World Know About Bepto

Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.

Application

ANYTHING YOU COULDN’T FIND?
Talk With Our Sales

Bepto focuses on the global market and provides our clients with products suitable for the local market:

SEND US AN EMAIL
Contact Us

Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.

Form Contact 2
Bepto Logo red
Get More Benefits Since Submit The Info Form
Form Contact