Specializing in the production of insulation products

JDZX9-35 Indoor Voltage Transformer 35kV Single-Phase Epoxy Resin Casting PT – Phase-to-Ground 100V/√3+100V/3 Triple Secondary 0.2/0.5/1/3/6P Class Open Delta Grounding Protection 1000VA High Output 40.5/95/200kV GB1207

Description:

JDZX9-35 Indoor Voltage Transformer 35kV Single-Phase Epoxy Resin Casting PT: Phase-to-ground measurement, 35kV/√3/100V/√3+100V/3 ratio, triple secondary winding, open delta grounding protection, 0.2/0.5/1/3/6P accuracy class, pillar-type fully enclosed, 40.5/95/200kV insulation, 1000VA max output, 1-second short circuit withstand, 50-60Hz, GB1207 IEC60044-2.

Applications:

Specialized JDZX9-35 indoor 35kV phase-to-ground voltage transformer featuring epoxy resin casting, pillar-type fully enclosed structure conforming to GB1207 and IEC60044-2 standards, rated frequency 50Hz or 60Hz, 40.5/95/200kV insulation level, designed for 35kV indoor power systems connected between phase and ground for electric energy measurement and relay protection with 100V/√3 secondary measuring winding and 100V/3 residual voltage winding.

Superior epoxy resin fully enclosed casting provides pollution-resistant, moisture-proof performance suitable for tropical climates, three units with residual voltage windings connected in open delta configuration for grounding protection, 1000VA high output capacity, withstands 1-second external short circuit at rated voltage excitation without damage, compact lightweight design enables flexible installation in any position or direction, secondary terminal box with three outlet holes ensures convenient safe reliable connections with anti-theft capability.

Specifications

JDZX9-35 Indoor Voltage Transformer 35kV Single-Phase Epoxy Resin Casting PT - Phase-to-Ground 100V/√3+100V/3 Triple Secondary 0.2/0.5/1/3/6P Class Open Delta Grounding Protection 1000VA High Output 40.5/95/200kV GB1207

JDZX9-35 Indoor Voltage Transformer 35kV Single-Phase Epoxy Resin Casting PT - Phase-to-Ground 100V/√3+100V/3 Triple Secondary 0.2/0.5/1/3/6P Class Open Delta Grounding Protection 1000VA High Output 40.5/95/200kV GB1207

Features

JDZX9-35 Indoor Voltage Transformer Specifications Parameter Unit
Brand Bepto Insulation Systems
Model Number JDZX9-35 Series
Category Switchgear & HV PT (High Voltage Potential Transformer)
Product Type 35kV Indoor Single-Phase Phase-to-Ground Epoxy Resin Casting Voltage Transformer with Triple Secondary Winding, Open Delta Grounding Protection, 0.2/0.5/1/3/6P Accuracy Class, 40.5/95/200kV Insulation, 1000VA High Output Capacity for 35kV Indoor Electric Energy Measurement and Relay Protection
Core Technology 35kV Indoor Single-Phase Phase-to-Ground Epoxy Resin Casting Design + Pillar-Type Fully Enclosed Structure + GB1207 and IEC60044-2 Standards Compliant + Rated Insulation Level (40.5/95/200kV) + Rated Frequency 50Hz or 60Hz + Phase-to-Ground Voltage Ratio (35kV/√3/100V/√3+100V/3) + Triple Secondary Winding Configuration + Open Delta Grounding Protection + Accuracy Classes (0.2, 0.5, 1, 3, 6P, 3P) + Rated Secondary Load 60-800VA + Maximum Output 500-1000VA + 1-Second External Short Circuit Withstand Capability + Pollution-Resistant + Moisture-Proof + Tropical Climate Suitable + Compact Lightweight Design + Flexible Installation + Secondary Terminal Box with Three Outlet Holes + Anti-Theft Capability + Proven Epoxy Resin Technology
Power (Voltage) 35kV
Installation Type Indoor
Phase Single Phase
Rated Voltage 35kV/√3 (20.2kV)
Voltage Ratio (Single Secondary) 35000/√3/100/√3 + 100/3 V
Voltage Ratio (Triple Secondary) 35000/√3/100/√3 + 100/√3 + 100/3 V
Secondary Measuring Winding 100V/√3 (57.7V) V
Residual Voltage Winding 100V/3 (33.3V) V
Connection Group (Single Unit) 1/1/1-12-12
Connection Group (Three Units) Y0/Y0/Δ-12-11 (Open Delta)
Rated Frequency 50Hz or 60Hz Hz
Accuracy Classes 0.2, 0.5, 1, 3, 6P (3P)
Insulation Level 40.5/95/200 kV
Max Output (Single Secondary) 1000 VA
Max Output (Triple Secondary) 500/500 VA
Rated Secondary Load (0.2 Class) 120 VA
Rated Secondary Load (0.5 Class) 300 VA
Rated Secondary Load (1 Class) 500 VA
Rated Secondary Load (3 Class) 800 VA
Rated Secondary Load (6P/3P Class) 150 VA
Rated Secondary Load (0.2/0.2 Dual) 60/60, 75/75 VA
Rated Secondary Load (0.5/0.5 Dual) 150/150 VA
Short Circuit Withstand 1 Second at Rated Voltage sec
Load Power Factor cos φ = 0.8 (Lagging)
Pollution Class Class II
Insulation Type Epoxy Resin Casting
Structure Type Pillar-Type Fully Enclosed Indoor Single-Phase
Voltage Level High Voltage (35kV)
Standards Compliance GB1207 and IEC60044-2
FOB Port Ningbo/Shanghai
Terms of Payment Western Union, T/T, Paypal
35kV High Voltage Yes (35kV Rated Voltage)
Indoor Epoxy Resin Casting Yes (Indoor Epoxy Resin Casting Insulation)
Single-Phase Yes (Single-Phase Configuration)
Indoor Construction Yes (Indoor Installation)
Phase-to-Ground Measurement Yes (Connected Between Phase and Ground)
100V/√3+100V/3 Ratio Yes (Special Phase-to-Ground Voltage Ratio)
Triple Secondary Winding Yes (Triple Secondary Available)
Open Delta Connection Yes (Residual Voltage Winding Open Delta)
Grounding Protection Yes (Open Delta for Ground Fault Protection)
1000VA High Output Yes (1000VA Maximum Output Capacity)
1-Second Short Circuit Withstand Yes (Withstands 1-Second External Short Circuit)
Pillar-Type Structure Yes (Pillar-Type Fully Enclosed Design)
50Hz or 60Hz Yes (Rated Frequency 50Hz or 60Hz)
GB1207 Compliant Yes (In Accordance with GB1207 Standard)
IEC60044-2 Compliant Yes (In Accordance with IEC60044-2 Standard)
40.5/95/200kV Insulation Yes (Rated Insulation Level)
0.2 Accuracy Class Yes (0.2 Metering Accuracy Class Available)
0.5 Accuracy Class Yes (0.5 Metering Accuracy Class Available)
1 Accuracy Class Yes (1 Monitoring Accuracy Class Available)
3 Accuracy Class Yes (3 Monitoring Accuracy Class Available)
6P/3P Protection Class Yes (6P/3P Protection Accuracy Class Available)
Pollution-Resistant Yes (Resistant to Pollution and Dirt)
Moisture-Proof Yes (Moisture-Proof Fully Enclosed Casting)
Tropical Climate Suitable Yes (Suitable for Tropical Areas)
Maintenance-Free Yes (No Special Maintenance Required)
Compact Lightweight Yes (Small Size, Light Weight)
Flexible Installation Yes (Any Position, Any Direction)
Secondary Terminal Box Yes (With Three Outlet Holes)
Anti-Theft Capability Yes (Anti-Theft Measures)
Model Type Rated Voltage Voltage Ratio Insulation Level Max Output Application
JDZX9-35 (Single Secondary) 35kV/√3 (20.2kV) 35kV/√3/100V/√3 + 100V/3 40.5/95/200kV 1000VA 35kV indoor phase-to-ground measurement + grounding protection with ultra-high output
JDZX9-35 (Triple Secondary) 35kV/√3 (20.2kV) 35kV/√3/100V/√3 + 100V/√3 + 100V/3 40.5/95/200kV 500/500VA 35kV indoor dual metering + grounding protection applications
Open Delta Grounding Protection Feature Description Benefit
Open Delta Configuration Three units with residual voltage windings connected in open delta Detects ground faults in 35kV systems
Residual Voltage Winding (100V/3) Dedicated 100V/3 winding for grounding protection Provides zero-sequence voltage for ground fault relays
Ground Fault Detection Detects single-phase ground faults in ungrounded systems Enables rapid ground fault protection and isolation
Three-Unit Connection Three single-phase transformers connected Y0/Y0/Δ-12-11 Complete three-phase phase-to-ground measurement with grounding protection
Ungrounded System Protection Ideal for ungrounded or resonant grounded 35kV systems Essential protection for high-resistance grounded systems
Zero-Sequence Voltage Monitoring Open delta provides zero-sequence voltage signal Enables selective ground fault protection schemes
Relay Protection Interface 100V/3 output directly interfaces with protection relays Simplified ground fault relay connection
Phase-to-Ground Measurement Feature Description Benefit
Phase-to-Ground Connection Connected between phase and ground (35kV/√3) Measures phase-to-ground voltage in 35kV systems
100V/√3 Secondary Voltage Secondary measuring winding outputs 100V/√3 (57.7V) Standard voltage for phase-to-ground metering
35kV/√3 Primary Voltage Primary voltage 35kV/√3 (20.2kV) Suitable for 35kV three-phase systems
Electric Energy Measurement Accurate phase-to-ground voltage for energy metering Precise billing-grade energy measurement
Relay Protection Provides voltage signal for protection relays Enables comprehensive 35kV protection schemes
Three-Phase Monitoring Three units provide complete three-phase monitoring Comprehensive 35kV system voltage monitoring
JDZX9-35 with single secondary winding (35 kV/√3 / 100 V/√3 + 100 V/3)
Accuracy Class Rated Secondary Load (VA) Max Output (VA) Application
0.2 120 1000 High-precision indoor phase-to-ground revenue metering for 35kV systems
0.5 300 1000 Standard indoor phase-to-ground metering and monitoring for 35kV systems
1 500 1000 General indoor phase-to-ground voltage monitoring for 35kV systems
3 800 1000 Indoor monitoring and instrumentation for 35kV systems
6P (3P) 150 1000 Indoor relay protection and grounding protection for 35kV systems
JDZX9-35 with three secondary windings (35 kV/√3 / 100 V/√3 + 100 V/√3 + 100 V/3)
Accuracy Class Combination Rated Secondary Load (VA) Max Output (VA) Application
0.2/0.2 60/60, 75/75 500/500 Dual high-precision indoor phase-to-ground metering for 35kV systems
0.5/0.5 150/150 500/500 Dual standard indoor phase-to-ground metering for 35kV systems
6P (3P) 150 500/500 Indoor relay protection and grounding protection for 35kV systems
1-Second Short Circuit Withstand Feature Description Benefit
1-Second External Short Circuit Withstands 1-second external short circuit at rated voltage Protects transformer during temporary system faults
Rated Voltage Excitation Tested at rated voltage excitation conditions Ensures reliability during normal operating voltage
No Damage No damage after 1-second short circuit Maintains accuracy and performance after fault events
Thermal Withstand Withstands thermal stress from short circuit current Robust construction for fault conditions
Mechanical Withstand Withstands mechanical stress from short circuit forces Durable design for system disturbances
Continuous Operation Continues operation after short circuit event Minimizes system downtime
Pillar-Type Fully Enclosed Structure Feature Description Benefit
Pillar-Type Design Vertical pillar-type indoor structure Optimal for indoor 35kV high voltage applications
Fully Enclosed Construction Complete enclosure of all electrical components Maximum protection from indoor environmental factors
Epoxy Resin Casting Fully enclosed epoxy resin casting insulation Excellent insulation and protection
Pollution-Resistant Resistant to indoor pollution and dirt Reliable operation in polluted indoor environments
Moisture-Proof Fully enclosed against moisture penetration Suitable for high-humidity indoor locations
Tropical Climate Suitable Designed for tropical climate conditions Reliable operation in hot humid climates
Maintenance-Free No special maintenance required Only periodic surface cleaning needed
Compact Lightweight Small size and light weight Easy handling and installation
Flexible Installation Suitable for any position, any direction installation Versatile mounting options
Secondary Terminal Box Feature Description Benefit
Secondary Terminal Box Dedicated terminal box for secondary connections Protected safe secondary wiring
Three Outlet Holes Box has three outlet terminal holes Flexible wiring from different directions
Convenient Connection Easy access for secondary wiring Simplified installation and maintenance
Safe Reliable Protected terminals ensure safety Prevents accidental contact with live terminals
Anti-Theft Capability Terminal box enables anti-theft measures Prevents unauthorized access and meter tampering
Different Direction Wiring Can lead out secondary wires from different directions Flexible routing for various installation configurations
1000VA High Output Capacity Feature Description Benefit
1000VA Maximum Output (Single Secondary) 1000VA maximum output capacity for single secondary configuration Supports extensive indoor 35kV multiple load connections
500/500VA Output (Triple Secondary) 500/500VA output capacity for triple secondary configuration High capacity for dual indoor 35kV metering applications
35kV High Voltage Application High output capacity for 35kV indoor systems Adequate capacity for 35kV indoor distribution loads
Multiple Load Support Can drive numerous indoor metering devices and relays Eliminates need for multiple 35kV indoor transformers
Indoor SCADA Systems Sufficient capacity for indoor data acquisition Enables advanced 35kV indoor monitoring and control
Future Expansion Excess capacity for indoor system upgrades Flexibility for 35kV indoor system expansion
Insulation Level Lightning Impulse Withstand Power Frequency Withstand Application Environment
40.5kV Rated voltage level Short-duration power frequency Standard 35kV indoor systems
95kV Lightning impulse Medium-duration withstand Lightning protection requirements for 35kV indoor
200kV Full lightning impulse Full insulation withstand Maximum insulation protection for 35kV indoor
35kV Indoor Phase-to-Ground Application Scenario Recommended Model Key Advantage Typical Installation
35kV Indoor Substations JDZX9-35 (Single Secondary) Phase-to-ground measurement + 1000VA high output 35kV indoor distribution substations
35kV Indoor Switchgear JDZX9-35 (Single Secondary) Pillar-type fully enclosed for indoor switchgear 35kV indoor metal-clad switchgear
35kV Grounding Protection JDZX9-35 (Single/Triple Secondary) Open delta grounding protection for ungrounded systems 35kV ungrounded or resonant grounded systems
35kV Dual Indoor Metering JDZX9-35 (Triple Secondary) Triple secondary for independent indoor metering + grounding protection 35kV indoor billing + monitoring + protection applications
35kV Indoor Energy Measurement JDZX9-35 (Single Secondary) High-precision phase-to-ground energy metering 35kV indoor revenue metering systems
35kV Indoor Relay Protection JDZX9-35 (Single/Triple Secondary) 100V/3 residual voltage for ground fault relays 35kV indoor protection relay systems
35kV Tropical Indoor Environments JDZX9-35 Series Moisture-proof suitable for tropical climates 35kV indoor installations in tropical regions
Feature JDZX9-35 (35kV Indoor Phase-to-Ground) JDZW-35 (35kV Outdoor Phase-to-Phase)
Installation Type Indoor Outdoor
Measurement Type Phase-to-ground (35kV/√3) Phase-to-phase (35kV)
Primary Voltage 35kV/√3 (20.2kV) 35kV
Secondary Voltage 100V/√3 + 100V/3 100V
Grounding Protection Yes (100V/3 open delta) No
Open Delta Connection Yes (three units) No
Epoxy Resin Type Standard indoor-grade Swiss Ciba CW5837 (outdoor premium)
Structure Type Pillar-type fully enclosed Pillar-type fully enclosed hermetically sealed
Maximum Output 1000VA (single), 500/500VA (triple) 1000VA (single), 800VA (dual)
Key Advantage Phase-to-ground + grounding protection + open delta Outdoor + Swiss Ciba premium + fully enclosed hermetically sealed
Typical Application Indoor substations, indoor switchgear, ungrounded systems Outdoor substations, overhead lines, oil-immersed replacement
Feature JDZX9-35 (35kV Indoor) JDZ(X)9-3/6/10Q(G) (3-10kV Indoor)
Voltage Level 35kV (high voltage) 3-10kV (medium voltage)
Installation Type Indoor Indoor
Measurement Type Phase-to-ground only Phase-to-phase (JDZ9) and phase-to-ground (JDZX9)
Grounding Protection Yes (100V/3 open delta) Yes (JDZX9 with 100V/3)
Maximum Output 1000VA (single), 500/500VA (triple) 500-600VA
Insulation Level 40.5/95/200kV 3.6-12/25-42/40-75kV
Key Advantage 35kV high voltage + grounding protection + 1000VA output 3-10kV medium voltage + dual measurement types + high output
Typical Application 35kV indoor substations, 35kV indoor switchgear 3-10kV indoor switchgear, 3-10kV ungrounded systems

Let The World Know About Bepto

Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.

Application

ANYTHING YOU COULDN’T FIND?
Talk With Our Sales

Bepto focuses on the global market and provides our clients with products suitable for the local market:

SEND US AN EMAIL
Contact Us

Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.

Form Contact 2
Bepto Logo red
Get More Benefits Since Submit The Info Form
Form Contact