LZW-35 Outdoor Current Transformer 35kV Medium Voltage CT – 10-2000A Dual Winding 0.2S/0.5/5P20 Class 200×In Thermal 500×In Dynamic Epoxy Resin Casting 40.5/95/185kV

Description:

LZW-35 Outdoor Current Transformer 35kV Medium Voltage CT: 10-2000A primary current, 0.2S/0.5/5P20 accuracy class, dual winding configuration, 200×In thermal capacity for 10-100A, 500×In dynamic current, 40.5/95/185kV insulation level, 15-30VA burden, epoxy resin casting, 5A/1A secondary, 50-60Hz, GB1208 IEC60044-1.

Applications:

Advanced LZW-35 Medium Voltage Current Transformer: Outdoor single-phase epoxy resin casting type CT conforming to GB1208 and IEC60044-1 standards, rated insulation level 40.5/95/185kV, rated frequency 50Hz or 60Hz, rated secondary current 5A or 1A, ambient temperature -25°C to +40°C, rated primary current range 10-2000A providing ultra-wide current coverage, dual winding configuration enabling simultaneous high-precision metering (0.2S/0.5 class) and protection (5P20 class) functions with burden capacity 15-30VA, exceptional thermal performance with 200×In (1s short-time thermal current) for 10-100A range ensuring superior short-circuit withstand capability, 500×In rated dynamic current for 10-100A range providing maximum safety margin.

Superior Medium Voltage Design and Exceptional Thermal Capacity: LZW-35 features robust outdoor epoxy resin casting construction ensuring reliable operation in harsh outdoor environments, exceptional 200 times rated current thermal capacity for low current range (10-100A) ensuring outstanding short-circuit protection, rated dynamic current up to 500×In for 10-100A range providing maximum safety margin, dual winding configuration supporting simultaneous high-precision metering and 5P20 protection relay functions, suitable for 35kV medium voltage switchgear, outdoor substations, power distribution systems, industrial power networks, renewable energy systems, and applications requiring precise current measurement from 10A to 2000A with exceptional thermal withstand capability and robust outdoor medium voltage construction.

Specifications

LZW-35 Outdoor Current Transformer 35kV Medium Voltage CT - 10-2000A Dual Winding 0.2S 0.5 5P20 Class 200×In Thermal 500×In Dynamic Epoxy Resin Casting 40.5 95 185kV

Features

LZW-35 Current Transformer Specifications Parameter Unit
Brand Bepto Insulation Systems
Model Number LZW-35
Category Switchgear & HV CT (High Voltage Current Transformer)
Product Type 35kV Outdoor Single-Phase Epoxy Resin Casting Type Medium Voltage Current Transformer with 10-2000A Range, 200×In Thermal Capacity, 500×In Dynamic Current, Dual Winding Configuration, 0.2S/0.5/5P20 Accuracy Class, 40.5/95/185kV Insulation for Metering & Protection
Core Technology Outdoor Single-Phase Epoxy Resin Casting Type + 35kV Medium Voltage Design + Exceptional 200×In Thermal Capacity for 10-100A Range + Superior 500×In Dynamic Current for 10-100A Range + Dual Winding Configuration + GB1208 and IEC60044-1 Standards Compliant + Rated Insulation Level 40.5/95/185kV + Rated Frequency 50Hz or 60Hz + Rated Secondary Current 5A or 1A + Ambient Temperature -25°C to +40°C + Rated Primary Current Range 10-2000A + Ultra-Wide Current Coverage + Flexible Accuracy Classes (0.2S/0.5/5P20) + Burden Capacity 15-30VA + 1s Short-Time Thermal Current 37.8-140kA for Higher Ranges + Rated Dynamic Current 94.5-200kA + Simultaneous High-Precision Metering and Protection Functions + Superior Short-Circuit Withstand Capability + Maximum Safety Margin + Robust Outdoor Construction
Power (Voltage) 35kV
Rated Voltage 35kV
Rated Insulation Level 40.5/95/185 kV
Rated Frequency 50Hz or 60Hz Hz
Rated Secondary Current 5A or 1A A
Rated Primary Current Range 10-2000 A
Ambient Temperature -25°C to +40°C °C
Structure Type Outdoor Single-Phase Epoxy Resin Casting Type
Winding Configuration Dual Winding (Two Windings)
Voltage Level Medium Voltage (35kV)
Installation Type Outdoor
Phase Single Phase
Standards Compliance GB1208 and IEC60044-1
FOB Port Ningbo/Shanghai
Terms of Payment Western Union, T/T, Paypal
Epoxy Resin Casting Yes (Outdoor Single-Phase Epoxy Resin Casting Type)
35kV Medium Voltage Yes (35kV Rated Voltage)
Medium Voltage CT Yes (Medium Voltage Current Transformer)
200×In Thermal Capacity Yes (200×In Thermal Current for 10-100A Range)
500×In Dynamic Current Yes (500×In Dynamic Current for 10-100A Range)
Dual Winding Configuration Yes (Two Windings for Metering and Protection)
Outdoor Construction Yes (Robust Outdoor Epoxy Resin Construction)
Exceptional Thermal Performance Yes (Superior Short-Circuit Withstand Capability)
Maximum Safety Margin Yes (500×In Dynamic Current for Maximum Safety)
50Hz or 60Hz Yes (Rated Frequency 50Hz or 60Hz)
35kV Rated Voltage Yes (Rated Voltage 35kV)
GB1208 Compliant Yes (In Accordance with GB1208 Standard)
IEC60044-1 Compliant Yes (In Accordance with IEC60044-1 Standard)
40.5/95/185kV Insulation Yes (Rated Insulation Level 40.5/95/185kV)
5A or 1A Secondary Yes (Rated Secondary Current 5A or 1A)
-25°C to +40°C Ambient Yes (Ambient Temperature -25°C to +40°C)
10-2000A Primary Range Yes (Rated Primary Current Range 10-2000A)
Ultra-Wide Current Coverage Yes (From 10A to 2000A Primary Current)
0.2S Accuracy Class Yes (0.2S Metering Accuracy Class Available)
0.5 Accuracy Class Yes (0.5 Metering Accuracy Class Available)
5P20 Protection Class Yes (5P20 Protection Accuracy Class Available)
15-30VA Burden Capacity Yes (Burden Capacity 15-30VA)
Rated primary current (A) Accuracy classes combination 0.2(S) (VA) 0.5 (VA) 5P20 (VA) 1s short-time thermal current (kA) Rated dynamic current (kA)
10–100 0.2(S)/5P20
0.5/5P20
200 × In 500 × In
150–200 0.2(S)/5P20
0.5/5P20
15 15 37.8 94.5
300–400 0.2(S)/5P20
0.5/5P20
15 54 110
500–600 0.2(S)/5P20
0.5/5P20
68.4 136
800–1000 0.2(S)/5P20
0.5/5P20
30 20 95.5 190
1200–2000 0.2(S)/5P20
0.5/5P20
140 200
Rated Primary Current (A) 200×In Thermal Current (kA) 500×In Dynamic Current (kA)
10 2 5
20 4 10
30 6 15
40 8 20
50 10 25
60 12 30
75 15 37.5
80 16 40
100 20 50
Primary Current Range Thermal Current (kA) Dynamic Current (kA) Accuracy Classes Burden Capacity Application
10-100A 200×In (2-20kA) 500×In (5-50kA) 0.2(S)/5P20, 0.5/5P20 Low-medium current with exceptional thermal protection
150-200A 37.8 94.5 0.2(S)/5P20, 0.5/5P20 15VA Medium current with high thermal protection
300-400A 54 110 0.2(S)/5P20, 0.5/5P20 15VA (0.2S) Medium-high current with high-precision metering
500-600A 68.4 136 0.2(S)/5P20, 0.5/5P20 High current with enhanced thermal protection
800-1000A 95.5 190 0.2(S)/5P20, 0.5/5P20 30VA (0.5), 20VA (5P20) Very high current with maximum burden capacity
1200-2000A 140 200 0.2(S)/5P20, 0.5/5P20 Ultra-high current with maximum thermal protection
Winding Configuration Accuracy Classes Combination Winding Function Application Scenario
0.2(S)/5P20 High-precision metering + 5P20 protection Precise billing and relay protection 10-2000A
0.5/5P20 Standard metering + 5P20 protection General metering and relay protection 10-2000A
Accuracy Class Application Current Range Availability Burden Capacity
0.2S High-precision metering, revenue billing, energy measurement 10-100A, 150-200A, 300-400A, 500-600A, 800-1000A, 1200-2000A 15VA (300-400A)
0.5 Standard metering, general billing, monitoring 10-100A, 150-200A, 300-400A, 500-600A, 800-1000A, 1200-2000A 15VA (150-200A), 30VA (800-1000A)
5P20 Relay protection, overcurrent protection 10-100A, 150-200A, 300-400A, 500-600A, 800-1000A, 1200-2000A 15VA (150-200A), 20VA (800-1000A)
Burden Capacity Accuracy Class Current Range Application
15VA 0.2S 300-400A High-precision metering for medium-high current
15VA 0.5, 5P20 150-200A Standard metering and protection for medium current
20VA 5P20 800-1000A Protection applications for very high current
30VA 0.5 800-1000A Standard metering for very high current
Current Range Thermal Current Dynamic Current Thermal/Dynamic Ratio Application Advantage
10-100A 200×In (2-20kA) 500×In (5-50kA) 2.5:1 Exceptional thermal capacity for low current range
150-200A 37.8kA 94.5kA 2.5:1 High thermal protection for medium current
300-400A 54kA 110kA 2.04:1 Balanced thermal and dynamic protection
500-600A 68.4kA 136kA 1.99:1 Enhanced thermal protection for high current
800-1000A 95.5kA 190kA 1.99:1 Maximum thermal protection for very high current
1200-2000A 140kA 200kA 1.43:1 Ultra-high thermal capacity for maximum current
Application Scenario Typical Current Range Key Advantage Typical Installation
35kV Medium Voltage Switchgear 10-2000A Ultra-wide current coverage Indoor/outdoor substations
Outdoor Substations 150-2000A Robust outdoor construction Transmission and distribution substations
Industrial Power Networks 300-2000A High thermal withstand capability Heavy industrial facilities
Renewable Energy Systems 10-600A Exceptional thermal capacity for variable loads Wind farms, solar farms
Power Distribution Systems 10-1000A Dual winding metering and protection Urban and rural distribution networks

Let The World Know About Bepto

Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.

Application

ANYTHING YOU COULDN’T FIND?
Talk With Our Sales

Bepto focuses on the global market and provides our clients with products suitable for the local market:

SEND US AN EMAIL
Contact Us

Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.

Form Contact 2
Bepto Logo red
Get More Benefits Since Submit The Info Form
Form Contact