Specializing in the production of insulation products

LQJ-10 Current Transformer 10kV Indoor High Voltage CT – 5-600A 0.2S/0.5S/10P Class 100×In Thermal 250×In Dynamic 12/42/75kV Epoxy Resin GB1208 IEC60044-1

Description:

LQJ-10 Current Transformer 10kV Indoor High Voltage CT: 5-600A primary current, 0.2S/0.5S/10P10 accuracy class, 100×In thermal capacity for 75-200A, 250×In dynamic current, 12/42/75kV insulation level, 10-15VA burden, 5A/1A secondary, 50/60Hz, GB1208 IEC60044-1 compliant, metering & protection.

Applications:

Advanced LQJ-10 Current Transformer: Indoor single-phase epoxy resin casting type CT conforming to GB1208 and IEC60044-1 standards, rated insulation level 12/42/75kV, rated frequency 50Hz or 60Hz, rated secondary current 5A or 1A, ambient temperature -5°C to +40°C, rated primary current range 5-600A providing wide current coverage, flexible accuracy class combinations including 0.2(S)/10P and 0.5(S)/10P with burden capacity 10-15VA, exceptional thermal performance with 90-100×In (1s thermal current) for 5-200A range ensuring superior short-circuit withstand capability, 220-250×In rated dynamic current for 5-200A providing maximum safety margin, optimized for diverse metering and protection requirements.

Superior Thermal Capacity and Wide Current Range: LQJ-10 features exceptional 90-100 times rated current thermal capacity for low-medium current range (5-200A) ensuring outstanding short-circuit protection, rated dynamic current up to 220-250×In for 5-200A range providing maximum safety margin, 1s thermal current 50-75kA for higher ranges (300-600A) with rated dynamic current 100-110kA, flexible accuracy class combinations supporting simultaneous high-precision metering and protection functions, suitable for 10kV switchgear, MV power distribution systems, substation metering, relay protection, energy management systems, industrial power monitoring, and applications requiring precise current measurement from 5A to 600A with exceptional thermal withstand capability.

Specifications

LQJ-10 Current Transformer 10kV Indoor High Voltage CT - 5-600A 0.2S 0.5S 10P Class 100×In Thermal 250×In Dynamic 12 42 75kV Epoxy Resin GB1208 IEC60044-1

Features

LQJ-10 Current Transformer Specifications Parameter Unit
Brand Bepto Insulation Systems
Model Number LQJ-10
Category Switchgear & HV CT (High Voltage Current Transformer)
Product Type 10kV Indoor Single-Phase Epoxy Resin Casting Type Current Transformer with 5-600A Range, 100×In Thermal Capacity, 250×In Dynamic Current, 0.2S/0.5S/10P Accuracy Class, 12/42/75kV Insulation for Metering & Relay Protection
Core Technology Indoor Single-Phase Epoxy Resin Casting Type + 10kV High Voltage Design + Exceptional 90-100×In Thermal Capacity for 5-200A Range + Superior 220-250×In Dynamic Current for 5-200A Range + GB1208 and IEC60044-1 Standards Compliant + Rated Insulation Level 12/42/75kV + Rated Frequency 50Hz or 60Hz + Rated Secondary Current 5A or 1A + Ambient Temperature -5°C to +40°C + Rated Primary Current Range 5-600A + Wide Current Coverage + Flexible Accuracy Classes (0.2(S)/10P, 0.5(S)/10P) + Burden Capacity 10-15VA + 1s Thermal Current 50-75kA for Higher Ranges + Rated Dynamic Current 100-110kA + Simultaneous High-Precision Metering and Protection Functions + Superior Short-Circuit Withstand Capability + Maximum Safety Margin
Power (Voltage) 10kV
Rated Voltage 10kV
Rated Insulation Level 12/42/75 kV
Rated Frequency 50Hz or 60Hz Hz
Rated Secondary Current 5A or 1A A
Rated Primary Current Range 5-600 A
Ambient Temperature -5°C to +40°C °C
Structure Type Indoor Single-Phase Epoxy Resin Casting Type
Installation Type Indoor
Phase Single Phase
Standards Compliance GB1208 and IEC60044-1
FOB Port Ningbo/Shanghai
Terms of Payment Western Union, T/T, Paypal
Epoxy Resin Casting Yes (Indoor Single-Phase Epoxy Resin Casting Type)
10kV High Voltage Yes (10kV Rated Voltage)
High Voltage CT Yes (High Voltage Current Transformer)
100×In Thermal Capacity Yes (100×In Thermal Current for 75-200A Range)
250×In Dynamic Current Yes (250×In Dynamic Current for 75-200A Range)
Exceptional Thermal Performance Yes (Superior Short-Circuit Withstand Capability)
Maximum Safety Margin Yes (220-250×In Dynamic Current for Maximum Safety)
50Hz or 60Hz Yes (Rated Frequency 50Hz or 60Hz)
10kV Rated Voltage Yes (Rated Voltage 10kV)
GB1208 Compliant Yes (In Accordance with GB1208 Standard)
IEC60044-1 Compliant Yes (In Accordance with IEC60044-1 Standard)
12/42/75kV Insulation Yes (Rated Insulation Level 12/42/75kV)
5A or 1A Secondary Yes (Rated Secondary Current 5A or 1A)
-5°C to +40°C Ambient Yes (Ambient Temperature -5°C to +40°C)
5-600A Primary Range Yes (Rated Primary Current Range 5-600A)
Wide Current Coverage Yes (From 5A to 600A Primary Current)
0.2S Accuracy Class Yes (0.2S Metering Accuracy Class Available)
0.5S Accuracy Class Yes (0.5S Metering Accuracy Class Available)
10P10 Protection Class Yes (10P10 Protection Accuracy Class Available)
10-15VA Burden Capacity Yes (Burden Capacity 10-15VA)
Rated primary current (A) Accuracy classes combination 0.2S / 0.5S (VA) 0.2 (VA) 0.5 (VA) 10P10 (VA) 1s thermal current (kA) Rated dynamic current (kA)
5–50 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 90 × In 220 × In
75–200 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 100 × In 250 × In
300, 400 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 50 100
500 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 56 110
600 0.2(S) / 10P
0.5(S) / 10P
10 10 10 15 75 110
Rated Primary Current (A) 90×In Thermal Current (kA) 220×In Dynamic Current (kA)
5 0.45 1.1
10 0.9 2.2
15 1.35 3.3
20 1.8 4.4
25 2.25 5.5
30 2.7 6.6
40 3.6 8.8
50 4.5 11
Primary Current Range Thermal/Dynamic Capacity Burden Capacity Application
5-50A 90×In / 220×In 0.2S: 10VA, 0.2: 10VA, 0.5: 10VA, 10P10: 15VA Low current with exceptional thermal protection
75-200A 100×In / 250×In 0.2S: 10VA, 0.2: 10VA, 0.5: 10VA, 10P10: 15VA Medium current with maximum thermal capacity
300-400A 50kA / 100kA 0.2S: 10VA, 0.2: 10VA, 0.5: 10VA, 10P10: 15VA Medium-high current with stable performance
500A 56kA / 110kA 0.2S: 10VA, 0.2: 10VA, 0.5: 10VA, 10P10: 15VA High current with enhanced thermal capacity
600A 75kA / 110kA 0.2S: 10VA, 0.2: 10VA, 0.5: 10VA, 10P10: 15VA Very high current with maximum protection
Accuracy Classes Combination Application Scenario Typical Current Range
0.2(S)/10P High-precision metering + protection 5-600A
0.5(S)/10P Standard metering + protection 5-600A

Let The World Know About Bepto

Bepto is a leading Chinese company in electrical insulation, focused on developing advanced solutions for future power systems. We support transmission and distribution safety and growth, with long-term partners including State Grid, ABB, Schneider, Siemens, and GE. Our services reach clients in over 22 countries.

Application

ANYTHING YOU COULDN’T FIND?
Talk With Our Sales

Bepto focuses on the global market and provides our clients with products suitable for the local market:

SEND US AN EMAIL
Contact Us

Unwavering in our dedication to customers and delivering cutting-edge innovations,Bepto stands as your steadfast ally on the journey ahead.

Form Contact 2
Bepto Logo red
Get More Benefits Since Submit The Info Form
Form Contact